SWITCHING CHARACTERISTICS
over recommended operating free-air temperature range, V
CC
= 2.5 V ± 0.2 V, V
I
= 2.5 V ± 0.2 V (unless otherwise noted)
(see Figure 12)
T
A
= –40°C
T
A
= 25°C
FROM TO
to 85°C
PARAMETER C
L
UNIT
(INPUT) (OUTPUT)
MIN TYP MAX MIN MAX
5 pF 1.8 2.3 3.1 0.5 6
10 pF 2.2 2.8 3.5 1 7.1
t
pd
A, B, or C Y ns
15 pF 2.6 3.2 5.2 1 7.9
30 pF 3.7 4.4 5.2 1.5 10
SWITCHING CHARACTERISTICS
over recommended operating free-air temperature range, V
CC
= 2.5 V ± 0.2 V, V
I
= 3.3 V ± 0.3 V (unless otherwise noted)
(see Figure 12)
T
A
= –40°C
T
A
= 25°C
FROM TO
to 85°C
PARAMETER C
L
UNIT
(INPUT) (OUTPUT)
MIN TYP MAX MIN MAX
5 pF 2 2.7 3.5 0.5 5.5
10 pF 2.4 3.1 3.9 1 6.5
t
pd
A, B, or C Y ns
15 pF 2.8 3.5 4.3 1 7.4
30 pF 4 4.7 5.5 1.5 9.5
SWITCHING CHARACTERISTICS
over recommended operating free-air temperature range, V
CC
= 3.3 V ± 0.3 V, V
I
= 1.8 V ± 0.15 V (unless otherwise noted)
(see Figure 12)
T
A
= –40°C
T
A
= 25°C
FROM TO
to 85°C
PARAMETER C
L
UNIT
(INPUT) (OUTPUT)
MIN TYP MAX MIN MAX
5 pF 1.6 2 2.5 0.5 8
10 pF 2 2.4 2.9 1 8.5
t
pd
A, B, or C Y ns
15 pF 2.3 2.8 3.3 1 9.1
30 pF 3.4 3.9 4.4 1.5 9.8
SWITCHING CHARACTERISTICS
over recommended operating free-air temperature range, V
CC
= 3.3 V ± 0.3 V, V
I
= 2.5 V ± 0.2 V (unless otherwise noted)
(see Figure 12)
T
A
= –40°C
T
A
= 25°C
FROM TO
to 85°C
PARAMETER C
L
UNIT
(INPUT) (OUTPUT)
MIN TYP MAX MIN MAX
5 pF 1.6 1.9 2.4 0.5 5.3
10 pF 2 2.3 2.7 1 6.1
t
pd
A, B, or C Y ns
15 pF 2.3 2.7 3.1 1 6.8
30 pF 3.4 3.8 4.2 1.5 8.5