Datasheet

NOTES: A. C
L
includes probe and jig capacitance.
B. Waveform 1 is for an output with internal conditions such that the output is low, except when disabled by the output control.
Waveform 2 is for an output with internal conditions such that the output is high, except when disabled by the output control.
C. All input pulses are supplied by generators having the following characteristics: PRR 10 MHz, Z
O
= 50 , t
r
/t
f
= 3 ns.
D. The outputs are measured one at a time, with one transition per measurement.
E. t
PLZ
and t
PHZ
are the same as t
dis
.
F. t
PZL
and t
PZH
are the same as t
en
.
G. All parameters and waveforms are not applicable to all devices.
5, 10, 15, 30 pF
V
CC
/2
V
CC
0.15 V
V
CC
= 1.2 V
± 0.1 V
V
CC
= 0.8 V
V
CC
= 1.5 V
± 0.1 V
V
CC
= 1.8 V
± 0.15 V
V
CC
= 2.5 V
± 0.2 V
V
CC
= 3.3 V
± 0.3 V
5, 10, 15, 30 pF
V
CC
/2
V
CC
0.1 V
5, 10, 15, 30 pF
V
CC
/2
V
CC
0.1 V
5, 10, 15, 30 pF
V
CC
/2
V
CC
0.1 V
C
L
V
M
V
I
V
5, 10, 15, 30 pF
V
CC
/2
V
CC
0.15 V
5, 10, 15, 30 pF
V
CC
/2
V
CC
0.3 V
Output
Waveform 1
S1 at 2 × V
CC
(see Note B)
Output
Waveform 2
S1 at GND
(see Note B)
V
OL
V
OH
t
PZL
t
PZH
t
PLZ
t
PHZ
V
CC
0 V
V
OL
+ V
V
OH
− V
0 V
V
CC
VOLTAGE WAVEFORMS
ENABLE AND DISABLE TIMES
LOW- AND HIGH-LEVEL ENABLING
Output
Control
V
CC
/2 V
CC
/2
V
CC
/2
V
CC
/2
t
PLZ
/t
PZL
t
PHZ
/t
PZH
2 × V
CC
GND
TEST S1
From Output
Under Test
C
L
(see Note A)
LOAD CIRCUIT
S1
GND
5 k
5 k
2 × V
CC
SN74AUP1G125
SCES595L JULY 2004REVISED FEBRUARY 2013
www.ti.com
PARAMETER MEASUREMENT INFORMATION
(Enable and Disable Times)
Figure 4. Load Circuit and Voltage Waveforms
10 Submit Documentation Feedback Copyright © 2004–2013, Texas Instruments Incorporated
Product Folder Links: SN74AUP1G125