Datasheet
SDAS111B − APRIL 1982 − REVISED DECEMBER 1994
3
POST OFFICE BOX 655303 • DALLAS, TEXAS 75265
POST OFFICE BOX 1443
• HOUSTON, TEXAS 77251−1443
switching characteristics (see Figure 1)
PARAMETER
FROM
(INPUT)
TO
(OUTPUT)
V
CC
= 4.5 V to 5.5 V,
C
L
= 50 pF,
R
L
= 500 Ω,
T
A
= MIN to MAX
†
UNIT
(INPUT)
(OUTPUT)
SN54ALS02A SN74ALS02A
MIN MAX MIN MAX
t
PLH
A or B
Y
1 16 1 12
ns
t
PHL
A or B
Y
1 11 1 10
ns
†
For conditions shown as MIN or MAX, use the appropriate value specified under recommended operating conditions.
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)
‡
Supply voltage, V
CC
7 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Input voltage, V
I
7 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Operating free-air temperature range, T
A
: SN54AS02 −55°C to 125°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SN74AS02 0°C to 70°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Storage temperature range −65°C to 150°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
‡
Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
recommended operating conditions
SN54AS02 SN74AS02
UNIT
MIN NOM MAX MIN NOM MAX
UNIT
V
CC
Supply voltage 4.5 5 5.5 4.5 5 5.5 V
V
IH
High-level input voltage 2 2 V
V
IL
Low-level input voltage 0.8 0.8 V
I
OH
High-level output current −2 −2 mA
I
OL
Low-level output current 20 20 mA
T
A
Operating free-air temperature −55 125 0 70 °C
electrical characteristics over recommended operating free-air temperature range (unless
otherwise noted)
PARAMETER
TEST CONDITIONS
SN54AS02 SN74AS02
UNIT
PARAMETER
TEST CONDITIONS
MIN TYP
§
MAX MIN TYP
§
MAX
UNIT
V
IK
V
CC
= 4.5 V, I
I
= −18 mA −1.2 −1.2 V
V
OH
V
CC
= 4.5 V to 5.5 V, I
OH
= −2 mA V
CC
−2 V
CC
−2 V
V
OL
V
CC
= 4.5 V, I
OL
= 20 mA 0.35 0.5 0.35 0.5 V
I
I
V
CC
= 5.5 V, V
I
= 7 V 0.1 0.1 mA
I
IH
V
CC
= 5.5 V, V
I
= 2.7 V 20 20 µA
I
IL
V
CC
= 5.5 V, V
I
= 0.4 V −0.5 −0.5 mA
I
O
¶
V
CC
= 5.5 V, V
O
= 2.25 V −30 −112 −30 −112 mA
I
CCH
V
CC
= 5.5 V, V
I
= 0 3.7 5.9 3.7 5.9 mA
I
CCL
V
CC
= 5.5 V, V
I
= 4.5 V 12.5 20.1 12.5 20.1 mA
§
All typical values are at V
CC
= 5 V, T
A
= 25°C.
¶
The output conditions have been chosen to produce a current that closely approximates one half of the true short-circuit output current, I
OS
.