instruction-register opcode description
The instruction-register opcodes are shown in Table 3. The following descriptions detail the operation of
each instruction.
Table 3. Instruction-Register Opcodes
BINARY CODE
†
BIT 7 → BIT 0
MSB → LSB
SCOPE OPCODE DESCRIPTION
SELECTED DATA
REGISTER
MODE
00000000 EXTEST/INTEST Boundary scan Boundary scan Test
10000001 BYPASS
‡
Bypass scan Bypass Normal
10000010 SAMPLE/PRELOAD Sample boundary Boundary scan Normal
00000011 INTEST/EXTEST Boundary scan Boundary scan Test
10000100 BYPASS
‡
Bypass scan Bypass Normal
00000101 BYPASS
‡
Bypass scan Bypass Normal
00000110 HIGHZ Control boundary to high impedance Bypass Modified test
10000111 CLAMP Control boundary to 1/0 Bypass Test
10001000 BYPASS
‡
Bypass scan Bypass Normal
00001001 RUNT Boundary run test Bypass Test
00001010 READBN Boundary read Boundary scan Normal
10001011 READBT Boundary read Boundary scan Test
00001100 CELLTST Boundary self test Boundary scan Normal
10001101 TOPHIP Boundary toggle outputs Bypass Test
10001110 SCANCN Boundary-control register scan Boundary control Normal
00001111 SCANCT Boundary-control register scan Boundary control Test
All others BYPASS Bypass scan Bypass Normal
†
Bit 7 is used to maintain even parity in the 8-bit instruction.
‡
The BYPASS instruction is executed in lieu of a SCOPE instruction that is not supported in the ’ABT8543.
boundary scan
This instruction conforms to the IEEE Standard 1149.1-1990 EXTEST and INTEST instructions. The BSR is
selected in the scan path. Data appearing at the device input pins is captured in the input BSCs, while data
appearing at the outputs of the normal on-chip logic is captured in the output BSCs. Data that has been scanned
into the input BSCs is applied to the inputs of the normal on-chip logic, while data that has been scanned into
the output BSCs is applied to the device output pins. The device operates in the test mode.
bypass scan
This instruction conforms to the IEEE Standard 1149.1-1990 BYPASS instruction. The bypass register is
selected in the scan path. A logic 0 value is captured in the bypass register during Capture-DR. The device
operates in the normal mode.
sample boundary
This instruction conforms to the IEEE Standard 1149.1-1990 SAMPLE/PRELOAD instruction. The BSR is
selected in the scan path. Data appearing at the device input pins is captured in the input BSCs, while data
appearing at the outputs of the normal on-chip logic is captured in the output BSCs. The device operates in the
normal mode.