Datasheet

 
  
  
SCBS239F − MARCH 1993 − REVISED JUNE 2004
4
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
electrical characteristics over recommended operating free-air temperature range (unless
otherwise noted)
PARAMETER
TEST CONDITIONS
T
A
= 25°C SN54ABT162245 SN74ABT162245
UNIT
PARAMETER
TEST CONDITIONS
MIN TYP
MAX MIN MAX MIN MAX
UNIT
V
IK
V
CC
= 4.5 V, I
I
= −18 mA −1.2 −1.2 −1.2 V
V
CC
= 5 V, I
OH
= −1 mA 3.8 2.5 2.5
A port
I
OH
= −1 mA 3.3 3 3
A port
V
CC
= 4.5 V
I
OH
= −3 mA 3.1 3 3.1
V
OH
V
CC
= 4.5 V
I
OH
= −12 mA 2.6* 2.6
V
V
OH
V
CC
= 5 V, I
OH
= −3 mA 3 3 3
V
B port
I
OH
= −3 mA 2.5 2.5 2.5
B port
V
CC
= 4.5 V
I
OH
= −24 mA 2
V
CC
= 4.5 V
I
OH
= −32 mA 2* 2
A port I
OL
= 12 mA 0.8 0.8 0.8
V
OL
B port
V
CC
= 4.5 V
I
OL
= 48 mA 0.45 0.45 0.45
V
V
OL
B port
V
CC
= 4.5 V
I
OL
= 64 mA 0.55* 0.55
V
V
hys
100 mV
I
I
Control
inputs
V
CC
= 5.5 V, V
I
= V
CC
or GND
±1 ±1 ±1
µA
I
I
A or B ports
V
CC
= 5.5 V, V
I
= V
CC
or GND
±20 ±20 ±20
µA
I
OZH
§
V
CC
= 5.5 V, V
O
= 2.7 V 10 10 10 µA
I
OZL
§
V
CC
= 5.5 V, V
O
= 0.5 V −10 −10 −10 µA
I
off
V
CC
= 0, V
I
or V
O
4.5 V ±100 ±100 µA
I
CEX
V
CC
= 5.5 V,
V
O
= 5.5 V
Outputs high 50 50 50 µA
I
O
A port
V
CC
= 5.5 V,
V
O
= 2.5 V
−25 −50 −100
−25 −90 −25 −100
mA
I
O
B port
V
CC
= 5.5 V, V
O
= 2.5 V
−50
−100 −180 −50 −180 −50 −180
mA
V
CC
= 5.5 V,
Outputs high 2 2 2
I
CC
A or B port
s
V
CC
= 5.5 V,
I
O
= 0,
V = V or GND
Outputs low 32 32 32
mA
I
CC
A or B ports
I
O
= 0,
V
I
= V
CC
or GND
Outputs disabled 2 2 2
mA
Data inputs
V
CC
= 5.5 V,
One input at 3.4 V,
Outputs enabled 1 2 2
I
CC
#
Data inputs
One input at 3.4 V,
Other inputs at
V
CC
or GND
Outputs disabled 0.05 1 0.05
mA
CC
Control
inputs
V
CC
= 5.5 V, One input at 3.4 V,
Other inputs at V
CC
or GND
1.5 1.5 1.5
C
i
V
I
= 2.5 V or 0.5 V 3 pF
C
io
V
O
= 2.5 V or 0.5 V 6 pF
* On products compliant to MIL-PRF-38535, this parameter does not apply.
All typical values are at V
CC
= 5 V.
This limit applies only to the SN74ABT162245.
§
The parameters I
OZH
and I
OZL
include the input leakage current.
Not more than one output should be tested at a time, and the duration of the test should not exceed one second.
#
This is the increase in supply current for each input that is at the specified TTL voltage level, rather than V
CC
or GND.