Datasheet

www.ti.com
DISSIPATION RATING TABLE
RECOMMENDED OPERATING CONDITIONS
2.4–
V
ID
2
V
ID
2
TIMING REQUIREMENTS
1
0
0 0.1 0.2 0.3
1.5
2.5
2
0.5
COMMON-MODE INPUT VOLTAGE
vs
DIFFERENTIAL INPUT VOLTAGE
– Common-Mode Input Voltage – VV
IC
V
ID
– Differential Input Voltage – V
0.4 0.5 0.6
Min
MAX at V
CC
= 3 V
MAX at V
CC
> 3.15 V
SN65LVDS22
SN65LVDM22
SLLS315C DECEMBER 1998 REVISED JUNE 2002
T
A
25°C DERATING FACTOR
(1)
T
A
= 85°C
PACKAGE
POWER RATING ABOVE T
A
= 25°C POWER RATING
D 1110 mW 8.9 mW/°C 577 mW
PW 839 mW 6.7 mW/°C 437 mW
(1) This is the inverse of the junction-to-ambient thermal resistance when board-mounted and with no air
flow.
MIN NOM MAX UNIT
V
CC
Supply voltage 3 3.3 3.6 V
V
IH
High-level input voltage S0, S1, 1DE, 2DE 2 V
V
IL
Low-level input voltage S0, S1, 1DE, 2DE 0.8 V
|V
ID
| Magnitude of differential input voltage 0.1 0.6 V
V
V
IC
Common-mode input voltage (see Figure 1 )
V
CC
–0.8 V
T
A
Operating free-air temperature 40 85 °C
PARAMETER MIN NOM MAX UNIT
t
su
Input to select setup time 1.6 ns
t
h
Input to select hold time See Figure 6 1 ns
t
switch
Select to switch output 3.2 5 ns
Figure 1. Common-Mode Input Voltage vs Differential Input Voltage
4
Submit Documentation Feedback