Datasheet

REG102
3
SBVS024F
www.ti.com
ELECTRICAL CHARACTERISTICS
Boldface limits apply over the specified temperature range, T
J
= 40°C to +85°C.
At T
J
= +25°C, V
IN
= V
OUT
+ 1V (V
OUT
= 2.5V for REG102-A), V
ENABLE
= 1.8V, I
OUT
= 5mA, C
NR
= 0.01µF, and C
OUT
= 0.1µF
(1)
, unless otherwise noted.
REG102NA
REG102GA
REG102UA
PARAMETER CONDITION MIN TYP MAX UNITS
OUTPUT VOLTAGE
Output Voltage Range V
OUT
REG102-2.5 2.5 V
REG102-2.8 2.8 V
REG102-2.85 2.85 V
REG102-3.0 3.0 V
REG102-3.3 3.3 V
REG102-5 5V
REG102-A 2.5 5.5 V
Reference Voltage V
REF
1.26 V
Adjust Pin Current I
ADJ
0.2 1 µA
Accuracy ±0.5 ±1.5 %
Over Temperature
±2.3 %
vs Temperature dV
OUT
/dT 50 ppm/°C
vs Line and Load
I
OUT
= 5mA to 250mA, V
IN
= (V
OUT
+ 0.4V) to 10V
±0.8 ±2.0 %
Over Temperature V
IN
= (V
OUT
+ 0.6V) to 10V ±2.8 %
DC DROPOUT VOLTAGE
(2)
V
DROP
I
OUT
= 5mA 4 10 mV
For all models I
OUT
= 250mA 150 220 mV
Over Temperature I
OUT
= 250mA 270 mV
VOLTAGE NOISE
f = 10Hz to 100kHz V
n
Without C
NR
(all models) C
NR
= 0, C
OUT
= 0 23µVrms/V V
OUT
µVrms
With C
NR
(all fixed voltage models) C
NR
= 0.01µF, C
OUT
= 10µF7µVrms/V V
OUT
µVrms
OUTPUT CURRENT
Current Limit
(3)
I
CL
340 400 470 mA
Over Temperature 300 490 mA
Short-Circuit Current Limit I
SC
150 mA
RIPPLE REJECTION
f = 120Hz 65 dB
ENABLE CONTROL
V
ENABLE
High (output enabled) V
ENABLE
1.8 V
IN
V
V
ENABLE
Low (output disabled) 0.2 0.5 V
I
ENABLE
High (output enabled) I
ENABLE
V
ENABLE
= 1.8V to V
IN
, V
IN
= 1.8V to 6.5
(4)
1 100 nA
I
ENABLE
Low (output disabled) V
ENABLE
= 0V to 0.5V 2 100 nA
Output Disable Time C
OUT
= 1.0µF, R
LOAD
= 13 50 µs
Output Enable Softstart Time C
OUT
= 1.0µF, R
LOAD
= 13 1.5 ms
THERMAL SHUTDOWN
Junction Temperature
Shutdown 160 °C
Reset from Shutdown 140 °C
GROUND PIN CURRENT
Ground Pin Current I
GND
I
OUT
= 5mA 400 500 µA
I
OUT
= 250mA 600 800 µA
Enable Pin Low V
ENABLE
0.5V 0.01 0.2 µA
INPUT VOLTAGE V
IN
Operating Input Voltage Range
(5)
1.8 10 V
Specified Input Voltage Range V
IN
> 1.8V V
OUT
+ 0.4 10 V
Over Temperature V
IN
> 1.8V V
OUT
+ 0.6 10 V
TEMPERATURE RANGE
Specified Range T
J
40 +85 °C
Operating Range T
J
55 +125 °C
Storage Range T
A
65 +150 °C
Thermal Resistance
SOT23-5 Surface-Mount
θ
JA
Junction-to-Ambient 200 °C/W
SO-8 Surface-Mount
θ
JA
Junction-to-Ambient 150 °C/W
SOT223-5 Surface-Mount
θ
JC
Junction-to-Case 15 °C/W
θ
JA
Junction-to-Ambient See Figure 8 °C/W
NOTES: (1) The REG102 does not require a minimum output capacitor for stability, however, transient response can be improved with proper capacitor selection.
(2) Dropout voltage is defined as the input voltage minus the output voltage that produces a 2% change in the output voltage from the value at V
IN
= V
OUT
+ 1V at fixed load.
(3) Current limit is the output current that produces a 10% change in output voltage from V
IN
= V
OUT
+ 1V and I
OUT
= 5mA.
(4) For V
ENABLE
> 6.5V, see typical characteristic
I
ENABLE
vs V
ENABLE
.
(5) The REG102 no longer regulates when V
IN
< V
OUT
+ V
DROP (MAX)
. In dropout, the impedance from V
IN
to V
OUT
is typically less than 1 at T
J
= +25°C.