Register 34h, DIR Input Biphase Source Select, Coax Amplifier Control
(Address: 34h, Write and Read)
DATA B7 B6 B5 B4 B3 B2 B1 B0
Reg Name RX0DIS RX1DIS RSV RSV RXSEL3 RXSEL2 RXSEL1 RXSEL0
Default Value 1 1 0 0 0 0 1 0
Memo
RX0DIS: Power Down for RXIN0 Coaxial Amplifier
0: Normal operation
1: Power down (default)
RX1DIS: Power Down for RXIN1 Coaxial Amplifier
0: Normal operation
1: Power down (default)
RXSEL[3:0]: DIR Input Biphase Signal Source Select
0000: RXIN0
0001: RXIN1
0010: RXIN2 (default)
0011: RXIN3
0100: RXIN4
0101: RXIN5
0110: RXIN6
0111: RXIN7
1000: RXIN8
1001: RXIN9
1010: RXIN10
1011: RXIN11
1100: Reserved
1101: Reserved
1110: Reserved
1111: TXOUT (internal DIT output)
NOTE
RX0DIS or RX1DIS must be set to '0', even when an S/PDIF, TTL, or OPTICAL input is
provided into RXIN0 or RXIN1, without use of the built-in COAX amplifier.