Datasheet


SLES105BFEBRUARY 2004 − REVISED NOVEMBER 2006
www.ti.com
29
DME: Digital De-Emphasis Control
This bit is available for read and write.
Default value: 0
DME = 0 De-emphasis disabled (default)
DME = 1 De-emphasis enabled
The DME bit is used to enable or disable the de-emphasis function for both channels.
MUTE: Soft Mute Control
This bit is available for read and write.
Default value: 0
MUTE = 0 MUTE disabled (default)
MUTE = 1 MUTE enabled
The MUTE bit is used to enable or disable the soft mute function for both channels.
Soft mute is operated as a 256-step attenuator. The speed for each step to – dB (mute) is determined by the attenuation
rate selected in the ATS register.
B15 B14 B13 B12 B11 B10 B9 B8 B7 B6 B5 B4 B3 B2 B1 B0
Register 19 R/W 0 0 1 0 0 1 1 REV ATS1 ATS0 OPE RSV DFMS FLT INZD
R/W: Read/Write Mode Select
When R/W = 0, a write operation is performed.
When R/W = 1, a read operation is performed.
Default value: 0
REV: Output Phase Reversal
This bit is available for read and write.
Default value: 0
REV = 0 Normal output (default)
REV = 1 Inverted output
The REV bit is used to invert the output phase for both channels.
ATS[1:0]: Attenuation Rate Select
These bits are available for read and write.
Default value: 00
ATS[1:0] Attenuation Rate Selection
00 LRCK/1 (default)
01 LRCK/2
10 LRCK/4
11 LRCK/8
The ATS[1:0] bits are used to select the rate at which the attenuator is decremented/incremented during level transitions.