Datasheet
V
OUT
V = 1Vrms
IN
OPA363
150kW19.5kW
220pF
1.8kW
3.3nF 47pF
R
11
3.92kW
R12
3.92kW
C
13
1000pF
R
14
3.48kW
C
15
1000pF
V
OUT
V
IN
R
1
3.92kW
R
3
1.33kW
C
4
1000pF
1/2
OPA2363
1/2
OPA2363
3
2
1
6
5
7
2
3
6
OPA363
OPA363, OPA2363
OPA364, OPA2364, OPA4364
SBOS259C –SEPTEMBER 2002–REVISED MAY 2013
www.ti.com
ACTIVE FILTERING
Low harmonic distortion and noise specifications plus high gain and slew rate make the OPA363 and OPA364
optimal candidates for active filtering. Figure 31 shows the OPA2363 configured as a low-distortion, 3rd-order
GIC (General Immittance Converter) filter. Figure 32 shows the implementation of a Sallen-Key, 3-pole, low-pass
Bessel filter.
Figure 31. The OPA2363 as a 3rd-Order, 40kHz, Low-Pass GIC Filter
Figure 32. The OPA363 or OPA364 Configured as a 3-Pole, 20kHz, Sallen-Key Filter
14 Submit Documentation Feedback Copyright © 2002–2013, Texas Instruments Incorporated
Product Folder Links: OPA363 OPA2363 OPA364 OPA2364 OPA4364