APPLICATION INFORMATION
port P6, P6.0 to P6.6, input/output with Schmitt trigger
P6.6/A6
P6IN.x
Module X IN
Pad Logic
EN
D
P6OUT.x
P6DIR.x
P6SEL.x
Module X OUT
Direction Control
From Module
0
1
0
1
Bus Keeper
To ADC
From ADC
0: Input
1: Output
x: Bit Identifier, 0 to 6 for Port P6
P6.0/A0 ..
Note: Not implemented in the MSP430x43x1 and MSP430x44x1 devices
NOTE: Analog signals applied to digital gates can cause current flow from the positive to the negative terminal. The throughput current flows if
the analog signal is in the range of transitions 01 or 10. The value of the throughput current depends on the driving capability of the
gate. For MSP430, it is approximately 100 µA.
Use P6SEL.x=1 to prevent throughput current. P6SEL.x should be set, even if the signal at the pin is not being used by the ADC12.
PnSel.x
PnDIR.x
Dir. Control
From Module
PnOUT.x Module X OUT PnIN.x Module X IN
P6Sel.0 P6DIR.0 P6DIR.0 P6OUT.0 DV
SS
P6IN.0 unused
P6Sel.1 P6DIR.1 P6DIR.1 P6OUT.1 DV
SS
P6IN.1 unused
P6Sel.2 P6DIR.2 P6DIR.2 P6OUT.2 DV
SS
P6IN.2 unused
P6Sel.3 P6DIR.3 P6DIR.3 P6OUT.3 DV
SS
P6IN.3 unused
P6Sel.4 P6DIR.4 P6DIR.4 P6OUT.4 DV
SS
P6IN.4 unused
P6Sel.5 P6DIR.5 P6DIR.5 P6OUT.5 DV
SS
P6IN.5 unused
P6Sel.6 P6DIR.6 P6DIR.6 P6OUT.6 DV
SS
P6IN.6 unused
NOTE: The signal at pins P6.x/Ax is used by the 12-bit ADC module.