Datasheet

MSP430F23x
MSP430F24x(1)
MSP430F2410
SLAS547I JUNE 2007REVISED DECEMBER 2012
www.ti.com
SVS (Supply Voltage Supervisor and Supply Voltage Monitor)
over recommended operating free-air temperature range (unless otherwise noted)
PARAMETER TEST CONDITIONS MIN TYP MAX UNIT
t
(SVSR)
dV
CC
/dt > 30 V/ms (see Figure 12) 1 150
µs
dV
CC
/dt 30 V/ms 2000
t
d(SVSon)
SVSon, switch from VLD = 0 to VLD 0, V
CC
= 3 V 150 300 µs
t
settle
VLD 0
(1)
12 µs
V
(SVSstart)
VLD 0, V
CC
/dt 3 V/s (see Figure 12) 1.55 1.7 V
VLD = 1 70 120 155 mV
V
CC
/dt 3 V/s (see Figure 12)
0.001 × 0.016 ×
VLD = 2 to 14
V
hys(SVS_IT-)
V
(SVS_IT-)
V
(SVS_IT-)
V
CC
/dt 3 V/s (see Figure 12), external voltage
VLD = 15 4.4 20 mV
applied on A7
V
(SVS_IT-)
VLD = 1 1.8 1.9 2.05
VLD = 2 1.94 2.1 2.25
VLD = 3 2.05 2.2 2.37
VLD = 4 2.14 2.3 2.48
VLD = 5 2.24 2.4 2.6
VLD = 6 2.33 2.5 2.71
VLD = 7 2.46 2.65 2.86
V
CC
/dt 3V/s (see Figure 12 and Figure 13)
VLD = 8 2.58 2.8 3
V
VLD = 9 2.69 2.9 3.13
VLD = 10 2.83 3.05 3.29
VLD = 11 2.94 3.2 3.42
VLD = 12 3.11 3.35 3.61
(2)
VLD = 13 3.24 3.5 3.76
(2)
VLD = 14 3.43 3.7
(2)
3.99
(2)
V
CC
/dt 3 V/s (see Figure 12 and Figure 13),
VLD = 15 1.1 1.2 1.3
external voltage applied on A7
I
CC(SVS)
(3)
VLD 0, V
CC
= 2.2 V, 3 V 10 15 µA
(1) t
settle
is the settling time that the comparator output needs to have a stable level after VLD is switched from VLD 0 to a different VLD
value somewhere between 2 and 15. The overdrive is assumed to be > 50 mV.
(2) The recommended operating voltage range is limited to 3.6 V.
(3) The current consumption of the SVS module is not included in the I
CC
current consumption data.
40 Submit Documentation Feedback Copyright © 2007–2012, Texas Instruments Incorporated