Datasheet
MSP430F23x
MSP430F24x(1)
MSP430F2410
www.ti.com
SLAS547I –JUNE 2007–REVISED DECEMBER 2012
12-Bit ADC, Temperature Sensor and Built-In V
MID
over recommended operating free-air temperature range (unless otherwise noted)
PARAMETER TEST CONDITIONS V
CC
MIN TYP MAX UNIT
Operating supply 2.2 V 40 120
REFON = 0, INCH = 0Ah,
I
SENSOR
current into AV
CC
µA
ADC12ON = 1, T
A
= 25°C
3V 60 160
terminal
(1)
2.2 V 986
V
SENSOR
(2)(3)
ADC12ON = 1, INCH = 0Ah, T
A
= 0°C mV
3V 986
2.2 V 3.55 3.55 ± 3%
TC
SENSOR
(3)
ADC12ON = 1, INCH = 0Ah mV/°C
3V 3.55 3.55 ± 3%
Sample time 2.2 V 30
ADC12ON = 1, INCH = 0Ah,
t
SENSOR(sample)
(3)
required if channel µs
Error of conversion result ≤ 1 LSB
3V 30
10 is selected
(4)
2.2 V NA
Current into divider
I
VMID
ADC12ON = 1, INCH = 0Bh µA
at channel 11
(5)
3V NA
2.2 V 1.1 1.1 ± 0.04
AV
CC
divider at ADC12ON = 1, INCH = 0Bh,
V
MID
V
channel 11 V
MID
is ~0.5 × V
AVCC
3V 1.5 1.5 ± 0.04
Sample time 2.2 V 1400
ADC12ON = 1, INCH = 0Bh,
t
VMID(sample)
required if channel ns
Error of conversion result ≤ 1 LSB
3 V 1220
11 is selected
(6)
(1) The sensor current I
SENSOR
is consumed if (ADC12ON = 1 and REFON = 1), or (ADC12ON = 1 AND INCH = 0Ah and sample signal is
high). Therefore it includes the constant current through the sensor and the reference.
(2) The temperature sensor offset can be as much as ±20°C. A single-point calibration is recommended to minimize the offset error of the
built-in temperature sensor.
(3) Limits characterized
(4) The typical equivalent impedance of the sensor is 51 kΩ. The sample time required includes the sensor-on time t
SENSOR(on)
(5) No additional current is needed. The V
MID
is used during sampling.
(6) The on-time t
VMID(on)
is included in the sampling time t
VMID(sample)
, no additional on time is needed.
Copyright © 2007–2012, Texas Instruments Incorporated Submit Documentation Feedback 65