Datasheet

MSP430F22x2
MSP430F22x4
www.ti.com
SLAS504G JULY 2006REVISED AUGUST 2012
Operational Amplifier (OA) Feedback Network, Noninverting Amplifier Mode (OAFCx = 4)
(MSP430F22x4 Only)
over recommended ranges of supply voltage and operating free-air temperature (unless otherwise noted)
PARAMETER TEST CONDITIONS V
CC
MIN TYP MAX UNIT
OAFBRx = 0 0.998 1 1.002
OAFBRx = 1 1.328 1.334 1.340
OAFBRx = 2 1.985 2.001 2.017
OAFBRx = 3 2.638 2.667 2.696
G Gain 2.2 V, 3 V
OAFBRx = 4 3.94 4 4.06
OAFBRx = 5 5.22 5.33 5.44
OAFBRx = 6 7.76 7.97 8.18
OAFBRx = 7 15 15.8 16.6
2.2 V -60
THD Total harmonic distortion/nonlinearity All gains dB
3 V -70
t
Settle
Settling time
(1)
All power modes 2.2 V, 3 V 7 12 µs
(1) The settling time specifies the time until an ADC result is stable. This includes the minimum required sampling time of the ADC. The
settling time of the amplifier itself might be faster.
Operational Amplifier (OA) Feedback Network, Inverting Amplifier Mode (OAFCx = 6)
(MSP430F22x4 Only)
(1)
over recommended ranges of supply voltage and operating free-air temperature (unless otherwise noted)
PARAMETER TEST CONDITIONS V
CC
MIN TYP MAX UNIT
OAFBRx = 1 -0.345 -0.335 -0.325
OAFBRx = 2 -1.023 -1.002 -0.979
OAFBRx = 3 -1.712 -1.668 -1.624
G Gain OAFBRx = 4 2.2 V, 3 V -3.1 -3 -2.9
OAFBRx = 5 -4.51 -4.33 -4.15
OAFBRx = 6 -7.37 -6.97 -6.57
OAFBRx = 7 -16.3 -14.8 -13.1
2.2 V -60
THD Total harmonic distortion/nonlinearity All gains dB
3 V -70
t
Settle
Settling time
(2)
All power modes 2.2 V, 3 V 7 12 µs
(1) This includes the 2 OA configuration "inverting amplifier with input buffer". Both OA needs to be set to the same power mode OAPMx.
(2) The settling time specifies the time until an ADC result is stable. This includes the minimum required sampling time of the ADC. The
settling time of the amplifier itself might be faster.
Copyright © 2006–2012, Texas Instruments Incorporated 55