Datasheet

MSP430F22x2
MSP430F22x4
www.ti.com
SLAS504G JULY 2006REVISED AUGUST 2012
Low-Power-Mode Supply Currents (Into V
CC
) Excluding External Current
(1)(2)
over recommended ranges of supply voltage and operating free-air temperature (unless otherwise noted)
PARAMETER TEST CONDITIONS T
A
V
CC
MIN TYP MAX UNIT
f
MCLK
= 0 MHz, 2.2 V 75 90
f
SMCLK
= f
DCO
= 1 MHz,
f
ACLK
= 32768 Hz,
Low-power mode 0
I
LPM0,1MHz
BCSCTL1 = CALBC1_1MHZ, µA
(LPM0) current
(3)
3 V 90 120
DCOCTL = CALDCO_1MHZ,
CPUOFF = 1, SCG0 = 0,
SCG1 = 0, OSCOFF = 0
f
MCLK
= 0 MHz, 2.2 V 37 48
f
SMCLK
= f
DCO(0, 0)
100 kHz,
Low-power mode 0 f
ACLK
= 0 Hz,
I
LPM0,100kHz
µA
(LPM0) current
(3)
RSELx = 0, DCOx = 0,
3 V 41 65
CPUOFF = 1, SCG0 = 0,
SCG1 = 0, OSCOFF = 1
-40°C to
f
MCLK
= f
SMCLK
= 0 MHz,
22 29
85°C
f
DCO
= 1 MHz,
2.2 V
f
ACLK
= 32768 Hz,
105°C 31
Low-power mode 2
I
LPM2
BCSCTL1 = CALBC1_1MHZ, µA
(LPM2) current
(4)
-40°C to
DCOCTL = CALDCO_1MHZ,
25 32
85°C
3 V
CPUOFF = 1, SCG0 = 0,
SCG1 = 1, OSCOFF = 0
105°C 34
-40°C 0.7 1.4
25°C 0.7 1.4
2.2 V
85°C 2.4 3.3
f
DCO
= f
MCLK
= f
SMCLK
= 0 MHz,
105°C 5 10
Low-power mode 3 f
ACLK
= 32768 Hz,
I
LPM3,LFXT1
µA
(LPM3) current
(4)
CPUOFF = 1, SCG0 = 1,
-40°C 0.9 1.5
SCG1 = 1, OSCOFF = 0
25°C 0.9 1.5
3 V
85°C 2.6 3.8
105°C 6 12
-40°C 0.4 1
25°C 0.5 1
2.2 V
85°C 1.8 2.9
f
DCO
= f
MCLK
= f
SMCLK
= 0 MHz,
f
ACLK
from internal LF oscillator
105°C 4.5 9
Low-power mode 3
I
LPM3,VLO
(VLO), µA
current, (LPM3)
(4)
-40°C 0.5 1.2
CPUOFF = 1, SCG0 = 1,
SCG1 = 1, OSCOFF = 0
25°C 0.6 1.2
3 V
85°C 2.1 3.3
105°C 5.5 11
-40°C 0.1 0.5
f
DCO
= f
MCLK
= f
SMCLK
= 0 MHz,
25°C 0.1 0.5
Low-power mode 4 f
ACLK
= 0 Hz, 2.2 V/
I
LPM4
µA
(LPM4) current
(5)
CPUOFF = 1, SCG0 = 1, 3 V
85°C 1.5 3
SCG1 = 1, OSCOFF = 1
105°C 4.5 9
(1) All inputs are tied to 0 V or V
CC
. Outputs do not source or sink any current.
(2) The currents are characterized with a Micro Crystal CC4V-T1A SMD crystal with a load capacitance of 9 pF. The internal and external
load capacitance is chosen to closely match the required 9 pF.
(3) Current for brownout and WDT clocked by SMCLK included.
(4) Current for brownout and WDT clocked by ACLK included.
(5) Current for brownout included.
Copyright © 2006–2012, Texas Instruments Incorporated 29