Datasheet

MSP430F21x2
www.ti.com
SLAS578J NOVEMBER 2007 REVISED JANUARY 2012
Outputs (Ports P1, P2, P3)
over recommended ranges of supply voltage and operating free-air temperature (unless otherwise noted)
PARAMETER TEST CONDITIONS V
CC
MIN MAX UNIT
I
OH(max)
= -1.5 mA
(1)
V
CC
- 0.25 V
CC
2.2 V
I
OH(max)
= -6 mA
(2)
V
CC
- 0.6 V
CC
V
OH
High-level output voltage V
I
OH(max)
= -1.5 mA
(1)
V
CC
- 0.25 V
CC
3 V
I
OH(max)
= -6 mA
(2)
V
CC
- 0.6 V
CC
I
OL(max)
= 1.5 mA
(1)
V
SS
V
SS
+ 0.25
2.2 V
I
OL(max)
= 6 mA
(2)
V
SS
V
SS
+ 0.6
V
OL
Low-level output voltage V
I
OL(max)
= 1.5 mA
(1)
V
SS
V
SS
+ 0.25
3 V
I
OL(max)
= 6 mA
(2)
V
SS
V
SS
+ 0.6
(1) The maximum total current, I
OH(max)
and I
OL(max)
, for all outputs combined, should not exceed ±12 mA to hold the maximum voltage drop
specified.
(2) The maximum total current, I
OH(max)
and I
OL(max)
, for all outputs combined, should not exceed ±48 mA to hold the maximum voltage drop
specified.
Output Frequency (Ports P1, P2, P3)
over recommended ranges of supply voltage and operating free-air temperature (unless otherwise noted)
PARAMETER TEST CONDITIONS V
CC
MIN TYP MAX UNIT
2.2 V 7.5
f
Px.y
Port output frequency (with load) P1.4/SMCLK, C
L
= 20 pF, R
L
= 1 k
(1)(2)
MHz
3 V 12
2.2 V 7.5
f
Port°CLK
Clock output frequency P2.0/ACLK, P1.4/SMCLK, C
L
= 20 pF
(2)
MHz
3 V 16
(1) Alternatively, a resistive divider with two 0.5-k resistors between V
CC
and V
SS
is used as load. The output is connected to the center
tap of the divider.
(2) The output voltage reaches at least 10% and 90% V
CC
at the specified toggle frequency.
Copyright © 20072012, Texas Instruments Incorporated Submit Documentation Feedback 23