Datasheet
0
1
t
d(BOR)
V
CC
V
(B_IT−)
V
hys(B_IT−)
V
CC(start)
MSP430F20x3
MSP430F20x2
MSP430F20x1
www.ti.com
SLAS491I –AUGUST 2005–REVISED DECEMBER 2012
POR and Brownout Reset (BOR)
(1)(2)
over recommended ranges of supply voltage and operating free-air temperature (unless otherwise noted)
PARAMETER TEST CONDITIONS V
CC
MIN TYP MAX UNIT
0.7 ×
V
CC(start)
See Figure 8 dV
CC
/dt ≤ 3 V/s V
V
(B_IT-)
V
(B_IT-)
See Figure 8 through Figure 10 dV
CC
/dt ≤ 3 V/s 1.71 V
V
hys(B_IT-)
See Figure 8 dV
CC
/dt ≤ 3 V/s 70 130 210 mV
t
d(BOR)
See Figure 8 2000 µs
Pulse duration needed at RST/NMI pin to 2.2 V,
t
(reset)
2 µs
accept reset internally 3 V
(1) The current consumption of the brownout module is already included in the I
CC
current consumption data. The voltage level V
(B_IT-)
+
V
hys(B_IT-)
is ≤ 1.8 V.
(2) During power up, the CPU begins code execution following a period of t
d(BOR)
after V
CC
= V
(B_IT-)
+ V
hys(B_IT-)
. The default DCO settings
must not be changed until V
CC
≥ V
CC(min)
, where V
CC(min)
is the minimum supply voltage for the desired operating frequency.
Figure 8. POR/Brownout Reset (BOR) vs Supply Voltage
Copyright © 2005–2012, Texas Instruments Incorporated Submit Documentation Feedback 27