Datasheet

ABSOLUTE MAXIMUM RATINGS
(1)
RECOMMENDED OPERATING CONDITIONS
LT1009
www.ti.com
................................................................................................................................................................. SLVS013N MAY 1987 REVISED MAY 2009
over operating free-air temperature range (unless otherwise noted)
MIN MAX UNIT
I
R
Reverse current 20 mA
I
F
Forward current 10 mA
D package 97
θ
JA
Package thermal impedance
(2) (3)
LP package 140 ° C/W
PW package 149
T
J
Operating virtual junction temperature 150 ° C
T
stg
Storage temperature range 65 150 ° C
(1) Stresses beyond those listed under " absolute maximum ratings " may cause permanent damage to the device. These are stress ratings
only, and functional operation of the device at these or any other conditions beyond those indicated under " recommended operating
conditions " is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
(2) Maximum power dissipation is a function of T
J
(max), θ
JA
, and T
A
. The maximum allowable power dissipation at any allowable ambient
temperature is P
D
= (T
J
(max) T
A
)/ θ
JA
. Operating at the absolute maximum T
J
of 150 ° C can affect reliability.
(3) The package thermal impedance is calculated in accordance with JESD 51-7.
MIN MAX UNIT
LT1009C 0 70
T
A
Operating free-air temperature range ° C
LT1009I 40 85
Copyright © 1987 2009, Texas Instruments Incorporated Submit Documentation Feedback 3
Product Folder Link(s): LT1009