Datasheet

LP3963, LP3966
www.ti.com
SNVS067H APRIL 2000REVISED APRIL 2013
The maximum allowable temperature rise (T
Rmax
) depends on the maximum ambient temperature (T
Amax
) of the
application, and the maximum allowable junction temperature (T
Jmax
):
T
Rmax
= T
Jmax
T
Amax
The maximum allowable value for junction to ambient Thermal Resistance, θ
JA
, can be calculated using the
formula:
θ
JA
= T
Rmax
/ P
D
LP3963 and LP3966 are available in TO-220 and DDPAK/TO-263 packages. The thermal resistance depends on
amount of copper area or heat sink, and on air flow. If the maximum allowable value of θ
JA
calculated above is
60 °C/W for TO-220 package and 60 °C/W for DDPAK/TO-263 package no heatsink is needed since the
package can dissipate enough heat to satisfy these requirements. If the value for allowable θ
JA
falls below these
limits, a heat sink is required.
HEATSINKING TO-220 PACKAGE
The thermal resistance of a TO-220 package can be reduced by attaching it to a heat sink or a copper plane on
a PC board. If a copper plane is to be used, the values of θ
JA
will be same as shown in next section for
DDPAK/TO-263 package.
The heatsink to be used in the application should have a heatsink to ambient thermal resistance,
θ
HA
θ
JA
θ
CH
θ
JC
.
In this equation, θ
CH
is the thermal resistance from the case to the surface of the heat sink and θ
JC
is the thermal
resistance from the junction to the surface of the case. θ
JC
is about 3°C/W for a TO-220 package. The value for
θ
CH
depends on method of attachment, insulator, etc. θ
CH
varies between 1.5°C/W to 2.5°C/W. If the exact value
is unknown, 2°C/W can be assumed.
HEATSINKING DDPAK/TO-263 PACKAGE
The DDPAK/TO-263 package uses the copper plane on the PCB as a heatsink. The tab of these packages are
soldered to the copper plane for heat sinking. Figure 23 shows a curve for the θ
JA
of DDPAK/TO-263 package for
different copper area sizes, using a typical PCB with 1 ounce copper and no solder mask over the copper area
for heat sinking.
Figure 23. θ
JA
vs Copper (1 Ounce) Area for DDPAK/TO-263 package
As shown in the figure, increasing the copper area beyond 1 square inch produces very little improvement. The
minimum value for θ
JA
for the DDPAK/TO-263 package mounted to a PCB is 32°C/W.
Figure 24 shows the maximum allowable power dissipation for DDPAK/TO-263 packages for different ambient
temperatures, assuming θ
JA
is 35°C/W and the maximum junction temperature is 125°C.
Copyright © 2000–2013, Texas Instruments Incorporated Submit Documentation Feedback 15
Product Folder Links: LP3963 LP3966