Datasheet

LMV321 SINGLE, LMV358 DUAL
LMV324 QUAD, LMV324S QUAD WITH SHUTDOWN
www.ti.com
SLOS263U AUGUST 1999REVISED JULY 2012
Shutdown Characteristics (LMV324S)
V
CC+
= 5 V, T
A
= 25°C (unless otherwise noted)
PARAMETER TEST CONDITIONS MIN TYP
(1)
MAX UNIT
Supply current in shutdown mode
I
CC(SHDN)
SHDN 0.6 V, T
A
= Full Temperature Range 5 μA
(per channel)
t
(on)
Amplifier turn-on time A
V
= 1, R
L
= Open (measured at 50% point) 2 μs
t
(off)
Amplifier turn-off time A
V
= 1, R
L
= Open (measured at 50% point) 40 ns
(1) Typical values represent the likely parametric nominal values determined at the time of characterization. Typical values depend on the
application and configuration and may vary over time. Typical values are not ensured on production material.
Copyright © 1999–2012, Texas Instruments Incorporated Submit Documentation Feedback 7