Datasheet

LMV341, LMV342, LMV344
www.ti.com
SLOS447H SEPTEMBER 2004REVISED JUNE 2012
ABSOLUTE MAXIMUM RATINGS
(1)
over operating free-air temperature range (unless otherwise noted)
MIN MAX UNIT
V
+
Supply voltage
(2)
5.5 V
V
ID
Differential input voltage
(3)
±5.5 V
V
I
Input voltage range (either input) 0 5.5 V
8 pin 97
D package
14 pin 86
DBV package 165
θ
JA
Package thermal impedance
(4) (5)
°C/W
DCK package 259
DGK package 172
PW package 113
T
J
Operating virtual junction temperature 150 °C
T
stg
Storage temperature range –65 150 °C
(1) Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings
only, and functional operation of the device at these or any other conditions beyond those indicated under “recommended operating
conditions” is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
(2) All voltage values (except differential voltages and V
+
specified for the measurement of I
OS
) are with respect to the network GND.
(3) Differential voltages are at IN+ with respect to IN.
(4) Maximum power dissipation is a function of T
J
(max), θ
JA
, and T
A
. The maximum allowable power dissipation at any allowable ambient
temperature is P
D
= (T
J
(max) – T
A
)/θ
JA
. Operating at the absolute maximum T
J
of 150°C can affect reliability.
(5) The package thermal impedance is calculated in accordance with JESD 51-7.
RECOMMENDED OPERATING CONDITIONS
MIN MAX UNIT
V
+
Supply voltage (single-supply operation) 2.5 5.5 V
T
A
Operating free-air temperature –40 125 °C
ESD PROTECTION
TEST CONDITIONS TYP UNIT
Human-Body Model 2000 V
Machine Model 200 V
Copyright © 2004–2012, Texas Instruments Incorporated Submit Documentation Feedback 3