Datasheet

LM9076
SNVS260L NOVEMEBER 2003REVISED MARCH 2013
www.ti.com
Electrical Characteristics for LM9076–3.3 (continued)
The following specifications apply for V
IN
= 14V; I
LOAD
= 10 mA; T
J
= +25C; C
OUT
= 10 μF, 0.5 < ESR < 4.0; unless
otherwise specified. Bold values indicate 40°C T
J
+125°C.
(1)(2)(3)
Minimum and Maximum limits are specified through
test, design or statistical correlation.
Symbol Parameter Conditions Min Typ Max Units
C
DELAY
PIN CHARACTERISTICS
C
DELAY
Charging V
IN
= 14V,
I
DELAY
-0.70 -0.42 -0.25 uA
Current V
DELAY
= 0V
V
OUT
< 4.0V,
V
OL
C
DELAY
pin low voltage 0.100 V
I
SINK
= I
DELAY
V
IN
= 14V, C
DELAY
=
0.001 uF
t
DELAY
Reset Delay Time V
OUT
rising from 0V, Δt 4.7 7.8 13.2 ms
from V
OUT
> V
OR
to
RESET pin HIGH
Electrical Characteristics for LM9076–5.0
The following specifications apply for V
IN
= 14V; V
SHUTDOWN
= Open; I
LOAD
= 10 mA; T
J
= +25°C; C
OUT
= 10 µF, 0.5 < ESR <
4.0; unless otherwise specified. Bold Values indicate 40°C T
J
125°C.
(1)(2)(3)
Minimum and Maximum limits are
specified through test, design, or statistical correlation.
Symbol Parameter Conditions Min Typ Max Units
LM9076–5.0 REGULATOR CHARACTERISTICS
4.925 5.00 5.075 V
20°C T
J
85°C
4.900 5.00 5.100 V
1 mA I
LOAD
150 mA
Output Voltage
1 mA I
LOAD
150 mA 4.850 5.00 5.150 V
V
IN
= 60V,
V
OUT
4.500 5.00 5.500 V
R
LOAD
= 1 k, t 40ms
Output Voltage Off V
SHUTDOWN
2V,
0 250 mV
LM9076 BMA only R
LOAD
= 1 k
V
IN
= -15V,
Reverse Battery 300 0 mV
R
LOAD
= 1 k
9.0V V
IN
16V,
4 25 mV
I
LOAD
= 10 mA
Line Regulation
ΔV
OUT
16V V
IN
40V,
17 35 mV
I
LOAD
= 10 mA
Load Regulation 1 mA I
LOAD
150 mA 42 60 mV
I
LOAD
= 10 mA 30 50 mV
V
DO
Dropout Voltage I
LOAD
= 50 mA 80 mV
I
LOAD
= 150 mA 150 250 mV
9V V
IN
16V,
25 45 μA
I
LOAD
= 100 uA
9V V
IN
40V,
125 160 μA
I
LOAD
= 10 mA
Ground Pin Current
9V V
IN
40V,
I
GND
0.6 mA
I
LOAD
= 50 mA
9V V
IN
16V,
3.6 4.5 mA
I
LOAD
= 150 mA
Ground Pin Current in 9V V
IN
40V,
15 25 μA
Shutdown Mode V
SHUTDOWN
= 2V
(1) Pulse testing used maintain constant junction temperature (T
J
).
(2) The regulated output voltage specification is not ensured for the entire range of V
IN
and output loads. Device operational range is limited
by the maximum junction temperature (T
J
). The junction temperature is influenced by the ambient temperature (T
A
), package
selection, input voltage (V
IN
), and the output load current. When operating with maximum load currents the input voltage and/or ambient
temperature will be limited. When operating with maximum input voltage the load current and/or the ambient temperature will be limited.
(3) Not Production tested, Specified by Design. Minimum, Typical, and/or Maximum values are provided for informational purposes only.
4 Submit Documentation Feedback Copyright © 2003–2013, Texas Instruments Incorporated
Product Folder Links: LM9076