Datasheet

LM158, LM158A, LM258, LM258A
LM358, LM358A, LM2904, LM2904V
DUAL OPERATIONAL AMPLIFIERS
SLOS068R − JUNE 1976 − REVISED JULY 2010
9
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
electrical characteristics at specified free-air temperature, V
CC
= 5 V (unless otherwise noted)
PARAMETER
TEST CONDITIONS
T
LM358A
UNIT
PARAMETER
TEST CONDITIONS
T
A
MIN TYP
§
MAX
UNIT
V
Input offset voltage
V
CC
= 5 V to 30 V,
25°C 2 3
mV
V
IO
Input offset voltage
V
CC
=
5
V
to
30
V
,
V
IC
= V
ICR(min)
, V
O
= 1.4 V
Full range 5
mV
a
V
IO
Average temperature coefficient of
input offset voltage
Full range 7 20 µV/°C
I
Input offset current
V 14V
25°C 2 30
nA
I
IO
Input offset current V
O
= 1.4 V
Full range 75
nA
a
I
IO
Average temperature coefficient of
input offset current
Full range 10 300 pA/°C
I
Input bias current
V 14V
25°C −15 −100
nA
I
IB
Input bias current V
O
= 1.4 V
Full range −200
nA
V
Common mode input voltage range
V 30 V
25°C
0 to
V
CC
− 1.5
V
V
ICR
Common-mode input voltage range V
CC
= 30 V
Full range
0 to
V
CC
− 2
V
R
L
2 k 25°C V
CC
− 1.5
V
OH
High-level output voltage
V 30 V
R
L
= 2 k Full range 26
V
V
OH
High level
output
voltage
V
CC
= 30 V
R
L
10 k Full range 27 28
V
V
OL
Low-level output voltage R
L
10 k Full range 5 20 mV
A
Lar
g
e-si
g
nal differential V
CC
= 15 V, V
O
= 1 V to 11 V,
25°C 25 100
V/mV
A
VD
Large signal
differential
voltage amplification
V
CC
=
15
V
,
V
O
=
1
V
to
11
V
,
R
L
2 k
Full range 15
V/mV
CMRR Common-mode rejection ratio 25°C 65 80 dB
k
SVR
Supply-voltage rejection ratio
(V
DD
/V
IO
)
25°C 65 100 dB
V
O1
/V
O2
Crosstalk attenuation f = 1 kHz to 20 kHz 25°C 120 dB
V
CC
= 15 V,
V 1V
Source
25°C −20 −30 −60
V
ID
= 1 V,
V
O
= 0
Source
Full range −10
mA
I
O
Output current V
CC
= 15 V,
V 1V
Sink
25°C 10 20
mA
V
ID
= −1 V,
V
O
= 15 V
Sink
Full range 5
V
ID
= −1 V, V
O
= 200 mV 25°C 30 µA
I
OS
Short-circuit output current V
CC
at 5 V, GND at −5 V, V
O
= 0 25°C ±40 ±60 mA
I
Supply current (two amplifiers)
V
O
= 2.5 V, No load Full range 0.7 1.2
mA
I
CC
Supply current (two amplifiers)
V
CC
= MAX, V
O
= 0.5 V, No load Full range 1 2
mA
All characteristics are measured under open-loop conditions, with zero common-mode input voltage, unless otherwise specified. MAX V
CC
for
testing purposes is 26 V for LM2904 and 30 V for others.
Full range is −55°C to 125°C for LM158A, −25°C to 85°C for LM258A, and 0°C to 70°C for LM358A.
§
All typical values are at T
A
= 25°C.