Datasheet

LM158, LM158A, LM258, LM258A
LM358, LM358A, LM2904, LM2904V
DUAL OPERATIONAL AMPLIFIERS
SLOS068R − JUNE 1976 − REVISED JULY 2010
5
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)
LM158, LM158A
LM258, LM258A
LM358, LM358A
LM2904V
LM2904 UNIT
Supply voltage, V
CC
(see Note 1) ±16 or 32 ±13 or 26 V
Differential input voltage, V
ID
(see Note 2) ±32 ±26 V
Input voltage, V
I
(either input) −0.3 to 32 −0.3 to 26 V
Duration of output short circuit (one amplifier) to ground
at (or below) 25°C free-air temperature (V
CC
15 V) (see Note 3)
Unlimited Unlimited
D package 97 97
DGK package 172 172
Package thermal impedance, q
JA
(see Notes 4 and 5)
P package 85 85
°C/W
Package
thermal
impedance,
q
JA
(see
Notes
4
and
5)
PS package 95 95
C/W
PW package 149 149
Package thermal impedance q (see Notes 6 and 7)
FK package 5.61
°C/W
Package thermal impedance, q
JC
(see Notes 6 and 7)
JG package 14.5
°C/W
LM158, LM158A −55 to 125
Operating free air temperature range T
LM258, LM258A −25 to 85
°C
Operating free-air temperature range, T
A
LM358, LM358A 0 to 70
°C
LM2904 −40 to 125 −40 to 125
Operating virtual junction temperature, T
J
150 150 °C
Case temperature for 60 seconds FK package 260 °C
Lead temperature 1,6 mm (1/16 inch) from case for 60 seconds JG package 300 300 °C
Storage temperature range, T
stg
−65 to 150 −65 to 150 °C
Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTES: 1. All voltage values, except differential voltages and V
CC
specified for measurement of I
OS
, are with respect to the network ground
terminal.
2. Differential voltages are at IN+ with respect to IN−.
3. Short circuits from outputs to V
CC
can cause excessive heating and eventual destruction.
4. Maximum power dissipation is a function of T
J
(max), q
JA
, and T
A
. The maximum allowable power dissipation at any allowable
ambient temperature is P
D
= (T
J
(max) − T
A
)/q
JA
. Operating at the absolute maximum T
J
of 150°C can affect reliability.
5. The package thermal impedance is calculated in accordance with JESD 51-7.
6. Maximum power dissipation is a function of T
J
(max), q
JC
, and T
C
. The maximum allowable power dissipation at any allowable case
temperature is P
D
= (T
J
(max) − T
C
)/q
JC
. Operating at the absolute maximum T
J
of 150°C can affect reliability.
7. The package thermal impedance is calculated in accordance with MIL-STD-883.