Datasheet

LM124, LM124A, LM224, LM224A, LM324, LM324A, LM2902, LM2902V,
LM224K, LM224KA, LM324K, LM324KA, LM2902K, LM2902KV, LM2902KAV
QUADRUPLE OPERATIONAL AMPLIFIERS
SLOS066T − SEPTEMBER 1975 − REVISED MARCH 2010
5
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)
LM2902
ALL OTHER
DEVICES
UNIT
Supply voltage, V
CC
(see Note 1) ±13 or 26 ±16 or 32 V
Differential input voltage, V
ID
(see Note 2) ±26 ±32 V
Input voltage, V
I
(either input) −0.3 to 26 −0.3 to 32 V
Duration of output short circuit (one amplifier) to ground at (or below) T
A
= 25°C,
V
CC
15 V (see Note 3)
Unlimited Unlimited
D package 86 86
DB package 96 96
Package thermal impedance, θ
JA
(see Notes 4 and 5)
N package 80 80
°C/W
Package
thermal
impedance,
θ
JA
(see
Notes
4
and
5)
NS package 76 76
PW package 113 113
FK package 5.61
Package thermal impedance, q
JC
(see Notes 6 and 7)
J package 15.05
°C/W
Package
thermal
impedance,
q
JC
(see
Notes
6
and
7)
W package 14.65
Operating virtual junction temperature, T
J
150 150 °C
Case temperature for 60 seconds FK package 260 °C
Lead temperature 1,6 mm (1/16 inch) from case for 60 seconds J or W package 300 300 °C
Storage temperature range, T
stg
−65 to 150 −65 to 150 °C
Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTES: 1. All voltage values (except differential voltages and V
CC
specified for the measurement of I
OS
) are with respect to the network GND.
2. Differential voltages are at IN+, with respect to IN−.
3. Short circuits from outputs to V
CC
can cause excessive heating and eventual destruction.
4. Maximum power dissipation is a function of T
J
(max), q
JA
, and T
A
. The maximum allowable power dissipation at any allowable
ambient temperature is P
D
= (T
J
(max) − T
A
)/q
JA
. Operating at the absolute maximum T
J
of 150°C can affect reliability.
5. The package thermal impedance is calculated in accordance with JESD 51-7.
6. Maximum power dissipation is a function of T
J
(max), q
JC
, and T
C
. The maximum allowable power dissipation at any allowable case
temperature is P
D
= (T
J
(max) − T
C
)/q
JC
. Operating at the absolute maximum T
J
of 150°C can affect reliability.
7. The package thermal impedance is calculated in accordance with MIL-STD-883.
ESD protection
TEST CONDITIONS TYP UNIT
Human-Body Model LM224K, LM224KA, LM324K, LM324KA, LM2902K, LM2902KV, LM2902KAV ±2 kV