Datasheet

LM1086
SNVS039H JUNE 2000REVISED MAY 2013
www.ti.com
Electrical Characteristics
Typicals and limits appearing in normal type apply for T
J
= 25°C. Limits appearing in Boldface type apply over the entire
junction temperature range for operation.
Min Typ Max
Symbol Parameter Conditions Units
(1) (2) (1)
V
REF
Reference Voltage LM1086-ADJ
I
OUT
= 10mA, V
IN
V
OUT
= 3V 1.238 1.250 1.262 V
10mA I
OUT
I
FULL LOAD
, 1.225 1.250 1.270 V
1.5V V
IN
V
OUT
15V
(3)
V
OUT
Output Voltage LM1086-1.8
1.782 1.8 1.818
(3)
I
OUT
= 0mA, V
IN
= 5V V
1.764 1.8 1.836
0 I
OUT
I
FULL LOAD
, 3.3V V
IN
18V
LM1086-2.5
2.475 2.50 2.525
I
OUT
= 0mA, V
IN
= 5V V
2.450 2.50 2.55
0 I
OUT
I
FULL LOAD
, 4.0V V
IN
18V
LM1086-2.85
2.82 2.85 2.88 V
I
OUT
= 0mA, V
IN
= 5V
2.79 2.85 2.91 V
0 I
OUT
I
FULL LOAD
, 4.35V V
IN
18V
LM1086-3.3
3.267 3.300 3.333 V
I
OUT
= 0mA, V
IN
= 5V
3.235 3.300 3.365 V
0 I
OUT
I
FULL LOAD
, 4.75V V
IN
18V
LM1086-3.45
3.415 3.45 3.484 V
I
OUT
= 0mA, V
IN
= 5V
3.381 3.45 3.519 V
0 I
OUT
I
FULL LOAD
, 4.95V V
IN
18V
LM1086-5.0
4.950 5.000 5.050 V
I
OUT
= 0mA, V
IN
= 8V
4.900 5.000 5.100 V
0 I
OUT
I
FULL LOAD
, 6.5V V
IN
20V
ΔV
OUT
Line Regulation LM1086-ADJ 0.015 0.2 %
(4)
I
OUT
=10mA, 1.5V (V
IN
-V
OUT
) 15V 0.035 0.2 %
LM1086-1.8 0.3 6
I
OUT
= 0mA, 3.3V V
IN
18V 0.6 6 mV
LM1086-2.5 0.3 6
I
OUT
= 0mA, 4.0V V
IN
18V 0.6 6 mV
LM1086-2.85 0.3 6 mV
I
OUT
= 0mA, 4.35V V
IN
18V 0.6 6 mV
LM1086-3.3 0.5 10 mV
I
OUT
= 0mA, 4.5V V
IN
18V 1.0 10 mV
LM1086-3.45 0.5 10 mV
I
OUT
= 0mA, 4.95V V
IN
18V 1.0 10 mV
LM1086-5.0 0.5 10 mV
I
OUT
= 0mA, 6.5V V
IN
20V 1.0 10 mV
ΔV
OUT
Load Regulation LM1086-ADJ 0.1 0.3 %
(4)
(V
IN
-V
OUT
) = 3V, 10mA I
OUT
I
FULL LOAD
0.2 0.4 %
LM1086-1.8 ,2.5, 2.85 3 12 mV
V
IN
= 5V, 0 I
OUT
I
FULL LOAD
6 20 mV
LM1086-3.3, 3.45 3 15 mV
V
IN
= 5V, 0 I
OUT
I
FULL LOAD
7 25 mV
LM1086-5.0 5 20 mV
V
IN
= 8V, 0 I
OUT
I
FULL LOAD
10 35 mV
Dropout Voltage LM1086-ADJ, 1.8, 2.5,2.85, 3.3, 3.45, 5
1.3 1.5 V
(5)
ΔV
REF
, ΔV
OUT
= 1%, I
OUT
= 1.5A
(1) All limits are specified by testing or statistical analysis.
(2) Typical Values represent the most likely parametric norm.
(3) I
FULL LOAD
is defined in the current limit curves. The I
FULL LOAD
Curve defines current limit as a function of input-to-output voltage. Note
that 15W power dissipation for the LM1086 is only achievable over a limited range of input-to-output voltage.
(4) Load and line regulation are measured at constant junction temperature, and are specified up to the maximum power dissipation of
15W. Power dissipation is determined by the input/output differential and the output current. Ensured maximum power dissipation will
not be available over the full input/output range.
(5) Dropout voltage is specified over the full output current range of the device.
4 Submit Documentation Feedback Copyright © 2000–2013, Texas Instruments Incorporated
Product Folder Links: LM1086