Datasheet

www.ti.com
12
11
10
9
8
7
6
5
4
3
2
1
0
5
0 15 20
Out
put Voltage (V)
Output Current (mA)
25
30
+25 C°
+25 C°
–40 C°
–40 C°
+125 C°
+125 C°
V =12V
S
Sourcing Current
V =3V
S
Sourcing Current
Output stage is designed
to source current. Current
sinkingcapabiltyis
approximately400 A.m
10
3.5
3.0
2.5
2.0
1.5
1.0
0.5
0
I
(mA)
Q
Output Voltage (V)
0
1 2
3
4
5
6
7
8 9 10
2.50
2.25
2.00
1.75
1.50
1.25
1.00
I (mA)
Q
V (V)
CM
V =100mV
SENSE
V =0mV
SENSE
V =12V
S
V =12V
S
V =2.7V
S
V =2.7V
S
–16
–12
–8
–4
0
4
8
12
16 20
24 28 32 36
34
30
26
22
18
14
10
6
2.5
3.5 4.5 5.5 6.5 7.5 8.5 9.5 11.5 17
10.5
O
utput Short--Circuit Current (mA)
Supply Voltage (V)
18
+125 C°
+25 C°
–40 C°
Out
put Voltage (50mV/div)
Time(2 s/div)m
G = 20
V
SENSE
=10mVto20mV
Output Voltage (500mV/div)
Time(2 s/div)m
G = 20
V
SENSE
=10mVto100mV
INA206
INA207
INA208
SBOS360E JUNE 2006 REVISED OCTOBER 2007
TYPICAL CHARACTERISTICS (continued)
All specifications at T
A
= +25 ° C, V
S
= +12V, V
IN+
= 12V, and V
SENSE
= 100mV, unless otherwise noted.
POSITIVE OUTPUT VOLTAGE SWING
vs OUTPUT CURRENT QUIESCENT CURRENT vs OUTPUT VOLTAGE
Figure 8. Figure 9.
QUIESCENT CURRENT OUTPUT SHORT-CIRCUIT CURRENT
vs COMMON-MODE VOLTAGE vs SUPPLY VOLTAGE
Figure 10. Figure 11.
STEP RESPONSE STEP RESPONSE
Figure 12. Figure 13.
8 Submit Documentation Feedback Copyright © 2006 2007, Texas Instruments Incorporated
Product Folder Link(s): INA206 INA207 INA208