Datasheet
www.ti.com
ORDERING INFORMATION
BasicModelNumber:2WProduct
VoltageInput:
5VIn
VoltageOutput:
5VOut
DualOutput:
PackageCode:
P=DIP-14
U=SO-28
DCP02 05 05 (D) ()
ABSOLUTE MAXIMUM RATINGS
ELECTRICAL CHARACTERISTICS
DCP02 Series
SBVS011K – MARCH 2000 – REVISED FEBRUARY 2008
This integrated circuit can be damaged by ESD. Texas Instruments recommends that all integrated circuits be handled with
appropriate precautions. Failure to observe proper handling and installation procedures can cause damage.
ESD damage can range from subtle performance degradation to complete device failure. Precision integrated circuits may be more
susceptible to damage because very small parametric changes could cause the device not to meet its published specifications.
For the most current package and ordering information, see the Package Option Addendum at the end of this
data sheet, or see the TI website at www.ti.com.
Supplemental Ordering Information
Over operating free-air temperature range (unless otherwise noted)
(1)
PARAMETER DCP02 Series UNIT
5V input models 7 V
12V input models 15 V
Input Voltage
15V input models 18 V
24V input models 29 V
Storage temperature range – 60 to +125 ° C
(1) Stresses beyond those listed under Absolute Maximum Ratings may cause permanent damage to the device. These are stress ratings
only, and functional operation of the device at these or any other conditions beyond those indicated under recommended operating
conditions is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
At T
A
= +25 ° C, unless otherwise noted.
PARAMETER TEST CONDITIONS MIN TYP MAX UNIT
OUTPUT
Power 100% full load 2 W
Ripple Output capacitor = 1 µ F, 50% load 20 mV
PP
Room to cold 0.046 %/ ° C
Voltage vs. Temperature
Room to hot 0.016 %/ ° C
INPUT
Voltage range on V
S
– 10 10 %
ISOLATION
1s Flash test 1 kVrms
Voltage
60s test, UL1950
(1)
1 kVrms
LINE REGULATION
V
S
(min) to V
S
(typ) 1 15 %
Output Voltage I
O
= constant
(2)
V
S
(typ) to V
S
(max) 1 15 %
(1) During UL1950 recognition tests only.
(2) I
OUT
≥ 10% load current
2 Submit Documentation Feedback Copyright © 2000 – 2008, Texas Instruments Incorporated
Product Folder Link(s): DCP02 Series