Datasheet

www.ti.com
0.000
0.025
0.050
0.075
0.100
0.125
0.150
0 1 2 3 4 5
I
SINK
- Sink Current - mA
V
OUT
- Output Voltage - V
V
DD
= 2.7 V
V
DD
= 5.5 V
DAC Loaded With 000
H
Typical For All Channels
5.30
5.35
5.40
5.45
5.50
0 1 2 3 4 5
I
SOURCE
− Source Current − mA
V
OUT
− Output Voltage − V
DAC Loaded With CFF
H
V
DD
= 5.5 V
Typical For All Channels
2.3
2.4
2.5
2.6
2.7
0 1 2 3 4 5
I
SOURCE
− Source Current − mA
V
OUT
− Output Voltage − V
DAC Loaded With CFF
H
V
DD
= 2.7 V
Typical For All Channels
Digital Input Code
0
100
200
300
400
500
600
700
800
0 128 256 384 512 640 768 896
I
DD
− Supply Current − µA
V
DD
= 2.7 V
V
DD
= 5.5 V
All Channels Powered, No Load
1023
T
A
- Free-Air Temperature - °C
0
100
200
300
400
500
600
700
-40 -10 20 50 80 110
I
DD
- Supply Current - µA
V
DD
= 2.7 V
V
DD
= 5.5 V
All Channels Powered, No Load
V
DD
- Supply Voltage - V
200
250
300
350
400
450
500
550
600
650
700
2.7 3.1 3.5 3.9 4.3 4.7 5.1 5.5
I
DD
- Supply Current - µA
All DACs Powered, No Load
DAC6573
SLAS402 NOVEMBER 2003
TYPICAL CHARACTERISTICS (continued)
At T
A
= +25 ° C, unless otherwise noted.
SINK CURRENT CAPABILITY SOURCE CURRENT CAPABILITY
AT NEGATIVE RAIL AT POSITIVE RAIL
Figure 13. Figure 14.
SOURCE CURRENT CAPABILITY SUPPLY CURRENT
AT POSITIVE RAIL vs DIGITAL INPUT CODE
Figure 15. Figure 16.
SUPPLY CURRENT SUPPLY CURRENT
vs TEMPERATURE vs SUPPLY VOLTAGE
Figure 17. Figure 18.
8