Datasheet

6
D
S
to SH
CP
Setup Time
D
n
to ST
CP
Setup Time
t
H
4.5 10 - - 13 - - 15 - - ns
ST
CP
to SH
CP
Hold Time t
H
4.5 0 - - 0 - - 0 - - ns
D
S
to SH
CP
Hold Time
D
n
to ST
CP
Hold Time
t
H
4.5 3 - - 3 - - 3 - - ns
MR to SH
CP
Removal
Time
t
REM
4.5 10 - - 13 - - 15 - - ns
Switching Speciļ¬cations Input t
r
, t
f
= 6ns
PARAMETER SYMBOL
TEST
CONDITIONS V
CC
(V)
25
o
C -40
o
Cto85
o
C -55
o
C to 125
o
C
UNITSMIN TYP MAX MIN MAX MIN MAX
HC TYPES
Propagation Delay t
PLH,
t
PHL
C
L
= 50pF 2 - - 175 - 220 - 265 ns
SH
CP
to Q7 4.5 - - 35 - 44 - 53 ns
C
L
=15pF 5 - 14 - - - - - ns
C
L
= 50pF 6 - - 30 - 37 - 45 ns
PL to Q7 t
PLH,
t
PHL
C
L
= 50pF 2 - - 200 - 250 - 300 ns
4.5 - - 40 - 50 - 60 ns
C
L
=15pF 5 - 17 - - - - - ns
C
L
= 50pF 6 - - 34 - 43 - 51 ns
ST
CP
to Q7 t
PLH,
t
PHL
C
L
= 50pF 2 - - 240 - 300 - 360 ns
4.5 - - 48 - 60 - 72 ns
C
L
=15pF 5 - 20 - - - - - ns
C
L
= 50pF 6 - - 41 - 51 - 61 ns
MR to Q7 t
PLH,
t
PHL
C
L
= 50pF 2 - - 175 - 220 - 265 ns
4.5 - - 35 - 44 - 53 ns
C
L
=15pF 5 - 14 - - - - - ns
C
L
= 50pF 6 - - 30 - 37 - 45 ns
Output Transition Time t
TLH
, t
THL
C
L
= 50pF 2 - - 75 - 95 - 110 ns
4.5 - - 15 - 19 - 22 ns
6 - - 13 - 16 - 19 ns
Input Capacitance C
I
C
L
= 50pF - - - 10 - 10 - 10 pF
Power Dissipation
Capacitance, (Notes 3, 4)
C
PD
- 5 - 13.5 - - - - - pF
HCT
Propagation Delay t
PLH,
t
PHL
SH
CP
to Q7 C
L
= 50pF 4.5 - - 38 - 48 - 57 ns
C
L
= 15pF 5 - 16 - - - - - ns
PL to Q7 t
PLH,
t
PHL
C
L
= 50pF 4.5 - - 48 60 72 ns
C
L
= 15pF 5 - 20 - - - - - ns
ST
CP
to Q7 t
PLH,
t
PHL
C
L
= 50pF 4.5 - - 56 70 84 ns
C
L
= 15pF 5 - 23 - - - - - ns
Prerequisite for Switching Speciļ¬cations (Continued)
PARAMETER SYMBOL V
CC
(V)
25
o
C -40
o
C TO 85
o
C -55
o
C TO 125
o
C
UNITSMIN TYP MAX MIN TYP MAX MIN TYP MAX
CD54HC597, CD74HC597, CD74HCT597