Datasheet

5
Low-Level Output
Voltage φO Output
(Pin 10)
TTL Loads
V
OL
V
CC
or
GND
2.6 4.5 - - 0.26 - 0.33 - 0.4 V
High-Level Output
Voltage φO Output
(Pin 9)
TTL Loads
V
OH
V
IL
or V
IH
-3.2 4.5 3.98 - - 3.84 - 3.7 - V
Low-Level Output
Voltage φO Output
(Pin 9)
TTL Loads
V
OL
V
IH
or V
IL
(Note 3)
3.2 4.5 - 0.26 - 0.33 - 0.4 V
Input Leakage
Current
I
I
Any
Voltage
Between
V
CC
and
GND
- 5.5 - ±0.1 - ±1-±1 µA
Quiescent Device
Current
I
CC
V
CC
or
GND
0 5.5 - - 8 - 80 - 160 µA
Additional Quiescent
Device Current Per
Input Pin: 1 Unit Load
I
CC
(Note 4)
V
CC
- 2.1
- 4.5 to
5.5
- 100 360 - 450 - 490 µA
NOTES:
2. Limits not valid when pin 12 (instead of pin 11) is used as control input.
3. For pin 11 V
IH
= 3.15V, V
IL
= 0.9V.
4. For dual-supply systems theoretical worst case (V
I
= 2.4V, V
CC
= 5.5V) specification is 1.8mA.
DC Electrical Specifications (Continued)
PARAMETER SYMBOL
TEST
CONDITIONS
V
CC
(V)
25
o
C -40
o
C TO 85
o
C -55
o
C TO 125
o
C
UNITSV
I
(V) I
O
(mA) MIN TYP MAX MIN MAX MIN MAX
HCT Input Loading Table
INPUT UNIT LOADS
MR 0.35
NOTE: Unit Load is I
CC
limit specified in DC Electrical Specifica-
tions Table, e.g. 360µA max at 25
o
C.
Prerequisite for Switching Specifications
PARAMETER SYMBOL V
CC
(V)
25
o
C -40
o
C TO 85
o
C -55
o
C TO 125
o
C
UNITSMIN TYP MAX MIN TYP MAX MIN TYP MAX
HC TYPES
Maximum Input Pulse
Frequency
f
max
2 6 - - 5 - - 4 - - MHz
4.5 30 - - 25 - - 20 - - MHz
6 35 - - 29 - - 23 - - MHz
Input Pulse Width t
W
2 80 - - 100 - - 120 - - ns
4.5 16 - - 20 - - 24 - - ns
614- -17- -20- -ns
Reset Removal Time t
REM
2 100 - - 125 - - 150 - - ns
4.5 20 - - 25 - - 30 - - ns
617- -21- -26- -ns
CD54/74HC4060, CD54/74HCT4060