Datasheet

HCT
V
CC
− GND (V)
V
CC
− V
EE
(V)
8
6
4
2
0
0 2 4 6 8 10 12
HC
HCT
V
CC
− GND (V)
V
EE
− GND (V)
8
6
4
2
0
0 −2 −4 −6 −8
HC
CD/74HC4051, CD54/74HCT4051, CD54/74HC4052,
SCHS122J NOVEMBER 1997 REVISED FEBRUARY 2011
www.ti.com
Recommended Operating Area as a Function of Supply Voltages
Figure 1.
Figure 2.
DC Electrical Specifications
AMBIENT TEMPERATURE, T
A
TEST CONDITIONS
40°C to 55°C to
25°C
PARAMETER 85°C 125°C UNIT
V
IS
V
I
V
EE
V
CC
MIN TYP MAX MIN MAX MIN MAX
(V) (V) (V) (V)
HC Types
2 1.5 1.5 1.5
V
IH
High-level input voltage 4.5 3.15 3.15 3.15 0 V
6 4.2 4.2 4.2
2 0.5 0.5 0.5
V
IL
Low-level input voltage 4.5 1.35 1.35 1.35 V
6 1.8 1.8 1.8
0 4.5 70 160 200 240
V
CC
or V
EE
0 6 60 140 175 210
I
O
= 1 mA
4.5 4.5 40 120 150 180
r
ON
ON resistance (see V
IL
or V
IH
Ω
0 4.5 90 180 225 270
Figure 11)
V
CC
to V
EE
0 6 80 160 200 240
4.5 4.5 45 130 162 195
0 4.5 10
Maximum ON resistance
Δr
ON
0 6 8.5 Ω
between any two channels
4.5 4.5 5
1 and 2 For switch OFF:
0 6 ±0.1 ±1 ±1
channels When V
IS
= V
CC
,
V
OS
= V
EE
,
4053 5 5 ±0.1 ±1 ±1
When V
IS
= V
EE
,
Switch ON/OFF
V
OS
= V
CC,
4 channels 0 6 ±0.1 ±1 ±1
I
IZ
leakage V
IL
or V
IH
μA
For switch ON:
current
4052 5 5 ±0.2 ±2 ±2
All applicable
combinations of
8 channels 0 6 ±0.2 ±2 ±2
V
IS
and V
OS
4051 5 5 ±0.4 ±4 ±4
voltage levels
V
CC
or
I
IL
Control input leakage current 0 6 ±0.1 ±1 ±1 μA
GND
When V
IS
= V
EE
,
0 6 8 80 160 μA
Quiescent
V
OS
= V
CC
V
CC
or
I
CC
device I
O
= 0
GND
When V
IS
= V
CC
,
current
5 5 16 160 320 μA
V
OS
= V
EE
8 Submit Documentation Feedback © 19972011, Texas Instruments Incorporated
Product Folder Link(s): CD/74HC4051, CD54/74HCT4051, CD54/74HC4052,