Datasheet

4
Quiescent Device
Current
I
CC
V
CC
or
GND
0 6 - - 8 - 80 - 160 µA
HCT TYPES
High Level Input
Voltage
V
IH
- - 4.5 to
5.5
2--2 - 2 - V
Low Level Input
Voltage
V
IL
- - 4.5 to
5.5
- - 0.8 - 0.8 - 0.8 V
High Level Output
Voltage
CMOS Loads
V
OH
V
IH
or V
IL
-0.02 4.5 4.4 - - 4.4 - 4.4 - V
High Level Output
Voltage
TTL Loads
-4 4.5 3.98 - - 3.84 - 3.7 - V
Low Level Output
Voltage
CMOS Loads
V
OL
V
IH
or V
IL
0.02 4.5 - - 0.1 - 0.1 - 0.1 V
Low Level Output
Voltage
TTL Loads
4 4.5 - - 0.26 - 0.33 - 0.4 V
Input Leakage
Current
I
I
V
CC
and
GND
0 5.5 - ±0.1 - ±1-±1 µA
Quiescent Device
Current
I
CC
V
CC
or
GND
0 5.5 - - 8 - 80 - 160 µA
Additional Quiescent
Device Current Per
Input Pin: 1 Unit Load
I
CC
(Note 2)
V
CC
-2.1
- 4.5 to
5.5
- 100 360 - 450 - 490 µA
NOTE:
2. For dual-supply systems theoretical worst case (V
I
= 2.4V, V
CC
= 5.5V) specification is 1.8mA.
HCT Input Loading Table
INPUT UNIT LOADS
D
S
0.2
D
n
0.3
PL, MR 1.5
ST
CP
, SH
CP
1.5
NOTE: Unit Load is I
CC
limit specified in DC Electrical Specifications
Table, e.g., 360µA max. at 25
o
C.
DC Electrical Specifications (Continued)
PARAMETER SYMBOL
TEST
CONDITIONS
V
CC
(V)
25
o
C -40
o
C TO 85
o
C -55
o
C TO 125
o
C
UNITSV
I
(V) I
O
(mA) MIN TYP MAX MIN MAX MIN MAX
Prerequisite for Switching Specifications
PARAMETER SYMBOL V
CC
(V)
25
o
C -40
o
C TO 85
o
C -55
o
C TO 125
o
C
UNITSMIN TYP MAX MIN TYP MAX MIN TYP MAX
HC TYPES
SH
CP
Frequency f
MAX
2 6 - - 5 - - 4 - - MHz
4.5 30 - - 25 - - 20 - - MHz
6 35 - - 29 - - 23 - - MHz
CD54HC597, CD74HC597, CD74HCT597