Datasheet

3
I
Absolute Maximum Ratings Thermal Information
DC Supply Voltage, V
CC
. . . . . . . . . . . . . . . . . . . . . . . . -0.5V to 6V
DC Input Diode Current, I
IK
For V
I
< -0.5V or V
I
> V
CC
+ 0.5V. . . . . . . . . . . . . . . . . . . . . .±20mA
DC Output Diode Current, I
OK
For V
O
< -0.5V or V
O
> V
CC
+ 0.5V . . . . . . . . . . . . . . . . . . . .±50mA
DC Output Source or Sink Current per Output Pin, I
O
For V
O
> -0.5V or V
O
< V
CC
+ 0.5V . . . . . . . . . . . . . . . . . . . .±50mA
DC V
CC
or Ground Current, I
CC or
I
GND
(Note 3) . . . . . . . . .±100mA
Operating Conditions
Temperature Range, T
A
. . . . . . . . . . . . . . . . . . . . . . -55
o
C to 125
o
C
Supply Voltage Range, V
CC
(Note 4)
AC Types. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1.5V to 5.5V
ACT Types . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4.5V to 5.5V
DC Input or Output Voltage, V
I
, V
O
. . . . . . . . . . . . . . . . . 0V to V
CC
Input Rise and Fall Slew Rate, dt/dv
AC Types, 1.5V to 3V . . . . . . . . . . . . . . . . . . . . . . . . . 50ns (Max)
AC Types, 3.6V to 5.5V. . . . . . . . . . . . . . . . . . . . . . . . 20ns (Max)
ACT Types, 4.5V to 5.5V. . . . . . . . . . . . . . . . . . . . . . . 10ns (Max)
Thermal Resistance (Typical, Note 5) θ
JA
(
o
C/W)
PDIP Package . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 90
SOIC Package . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 175
Maximum Junction Temperature (Plastic Package) . . . . . . . . . . 150
o
C
Maximum Storage Temperature Range . . . . . . . . . .-65
o
C to 150
o
C
Maximum Lead Temperature (Soldering 10s) . . . . . . . . . . . . . 300
o
C
(SOIC - Lead Tips Only)
CAUTION: Stresses above those listed in “Absolute Maximum Ratings” may cause permanent damage to the device. This is a stress only rating and operation
of the device at these or any other conditions above those indicated in the operational sections of this specification is not implied.
NOTES:
3. For up to 4 outputs per device, add ±25mA for each additional output.
4. Unless otherwise specified, all voltages are referenced to ground.
5. θ
JA
is measured with the component mounted on an evaluation PC board in free air.
DC Electrical Specifications
PARAMETER SYMBOL
TEST
CONDITIONS
V
CC
(V)
25
o
C
-40
o
C TO
85
o
C
-55
o
C TO
125
o
C
UNITSV
I
(V) I
O
(mA) MIN MAX MIN MAX MIN MAX
AC TYPES
High Level Input Voltage V
IH
- - 1.5 1.2 - 1.2 - 1.2 - V
3 2.1 - 2.1 - 2.1 - V
5.5 3.85 - 3.85 - 3.85 - V
Low Level Input Voltage V
IL
- - 1.5 - 0.3 - 0.3 - 0.3 V
3 - 0.9 - 0.9 - 0.9 V
5.5 - 1.65 - 1.65 - 1.65 V
High Level Output Voltage V
OH
V
IH
or V
IL
-0.05 1.5 1.4 - 1.4 - 1.4 - V
-0.05 3 2.9 - 2.9 - 2.9 - V
-0.05 4.5 4.4 - 4.4 - 4.4 - V
-4 3 2.58 - 2.48 - 2.4 - V
-24 4.5 3.94 - 3.8 - 3.7 - V
-75
(Note 6, 7)
5.5 - - 3.85 - - - V
-50
(Note 6, 7)
5.5----3.85 - V
CD54/74AC164, CD54/74ACT164