Datasheet
6
CD4051B
,
CD4052B
,
CD4053B
SCHS047I –AUGUST 1998–REVISED SEPTEMBER 2017
www.ti.com
Product Folder Links: CD4051B CD4052B CD4053B
Submit Documentation Feedback Copyright © 1998–2017, Texas Instruments Incorporated
(1) Peak-to-Peak voltage symmetrical about (V
DD
– V
EE
) / 2.
(2) Determined by minimum feasible leakage measurement for automatic testing.
(3) Does not apply to Hi-Rel CD4051BF and CD4051BFA3 devices.
6.5 Electrical Characteristics
over operating free-air temperature range, V
SUPPLY
= ±5 V, and R
L
= 100 Ω, (unless otherwise noted)
(1)
PARAMETER
TEST CONDITIONS MIN TYP MAX UNIT
V
IS
(V) V
EE
(V) V
SS
(V) V
DD
(V) TEMP
SIGNAL INPUTS (V
IS
) AND OUTPUTS (V
OS
)
Quiescent Device Current, I
DD
Max
5
–55°C 5
µA
–40°C 5
25°C 0.04 5
85°C 150
125°C 150
10
–55°C 10
–40°C 10
25°C 0.04 10
85°C 300
125°C 300
15
–55°C 20
–40°C 20
25°C 0.04 20
85°C 600
125°C 600
20
–55°C 100
–40°C 100
25°C 0.08 100
85°C 3000
125°C 3000
Drain to Source ON Resistance r
ON
Max
0 ≤ V
IS
≤ V
DD
0 0 5
–55°C 800
Ω
–40°C 850
25°C 470 1050
85°C 1200
125°C 1300
0 0 10
–55°C 310
–40°C 300
25°C 180 400
85°C 520
125°C 550
0 0 15
–55°C 200
–40°C 210
25°C 125 240
85°C 300
125°C 300
Change in ON Resistance
(Between Any Two Channels),
∆r
ON
0 0 5
25°C
15
Ω0 0 10 10
0 0 15 5
OFF Channel Leakage Current: Any Channel OFF (Max)
or ALL Channels OFF (Common OUT/IN) (Max)
0 0 18
–55°C ± 100
nA
–40°C
25°C ± 0.01 ± 100
(2)
85°C ± 1000
(2)
125°C
ON Channel Leakage Current: Any Channel ON (Max) or
ALL Channels ON (Common OUT/IN) (Max)
5 or 0 -5 0 10.5 85°C ± 300
(3)
nA
5 0 0 18 85°C ± 300
(3)
Capacitance
Input, C
IS
–5 –5 –5 25°C 5 pF
Output, C
OS
CD4051
25°C
30
CD4052 18
CD4053 9
Feed through, C
IOS
0.2