Class Subclass ID Subclass Offset Name Data Min Value Max Value Default Value Units
Type
Configuration 2 Safety 0 OT Chg I2 0 1200 550 0.1°C
Configuration 2 Safety 2 OT Chg Time U1 0 60 2 s
Configuration 2 Safety 3 OT Chg Recovery I2 0 1200 500 0.1°C
Configuration 2 Safety 5 OT Dsg I2 0 1200 600 0.1°C
Configuration 2 Safety 7 OT Dsg Time U1 0 60 2 s
Configuration 2 Safety 8 OT Dsg Recovery I2 0 1200 350 0.1°C
Configuration 32 Charge Inhibit Config 0 Charge Inhibit Temp Low I2 –400 1200 0 0.1°C
Configuration 32 Charge Inhibit Config 2 Charge Inhibit Temp High I2 –400 1200 450 0.1°C
Configuration 32 Charge Inhibit Config 4 Temp Hys I2 0 100 50 0.1°C
Configuration 34 Charge 2 Charging Voltage I2 0 4600 4200 mV
Configuration 34 Charge 4 Delta Temperature I2 0 500 50 0.1°C
Configuration 34 Charge 6 Suspend Temperature Low I2 –400 1200 –50 0.1°C
Configuration 34 Charge 8 Suspend Temperature High I2 –400 1200 550 0.1°C
Configuration 36 Charge Termination 2 Taper Current I2 0 1000 100 mA
Configuration 36 Charge 4 Minimum Taper Charge I2 0 1000 25 0.01mAh
Configuration 36 Charge Termination 6 Taper Voltage I2 0 1000 100 mV
Configuration 36 Charge Termination 8 Current Taper Window U1 0 60 40 s
Configuration 36 Charge Termination 7 TCA Set % I1 –1 100 100 %
Configuration 36 Charge Termination 8 TCA Clear % I1 –1 100 95 %
Configuration 36 Charge Termination 9 FC Set % I1 –1 100 100 %
Configuration 36 Charge Termination 10 FC Clear % I1 –1 100 98 %
Configuration 48 Data 4 Initial Standby Current I1 –128 0 –10 mA
Configuration 48 Data 5 Initial Max Load Current I2 –32,767 0 –500 mA
Configuration 48 Data 7 CC Threshold I2 100 32,767 900 mAh
Configuration 48 Data 10 Design Capacity I2 0 65,535 1000 mAh
Configuration 48 Data 12 Device Name S8 x x bq27510 –
Configuration 49 Discharge 0 SOC1 Set Threshold U1 0 255 150 mAh
Discharge 1 SOC1 Clear Threshold U1 0 255 175 mAh
Configuration 49 Discharge 2 SOCF Set Threshold U1 0 255 75 mAh
Configuration 49 Discharge 3 SOCF Clear Threshold U1 0 255 100 mAh
System Data 58 Manufacturer Info 0–31 Block A [0–31] H1 0x00 0xff 0x00 –
System Data 58 Manufacturer Info 32–63 Block B [0–31] H1 0x00 0xff 0x00 –
Configuration 64 Registers 0 Operation Configuration H2 0x0000 0xffff 0x0979 –
Configuration 64 Registers 3 Operation Configuration B H1 0x00 0xff 0xC0 –
Configuration 64 Registers 4 Batt Insert Delay U2 0 65535 0 –
Configuration 64 Registers 6 Sleep Insert Delay U1 0 255 0 –
Configuration 68 Power 0 Flash Update OK Voltage I2 0 4200 2800 mV
Configuration 68 Power 5 Sleep Current I2 0 100 10 mA
Configuration 68 Power 14 Hibernate Current U2 0 700 8 mA
Configuration 68 Power 16 Hibernate Voltage U2 2400 3000 2550 mV
Gas Gauging 80 IT Cfg 0 Load Select U1 0 255 1 –
Gas Gauging 80 IT Cfg 1 Load Mode U1 0 255 0 –
Gas Gauging 80 IT Cfg 23 Ra Filter U2 0 1000 800 –
Gas Gauging 80 IT Cfg 44 Terminate Voltage I2 0 32,767 3000 mV
Gas Gauging 80 IT Cfg 47 ResRelax Time U2 0 65535 200 s
Gas Gauging 80 IT Cfg 49 User Rate-mA I2 2000 –100 0 mA
Gas Gauging 80 IT Cfg 51 User Rate-mW I2 –7200 –350 0 10mW
Copyright © 2010, Texas Instruments Incorporated Submit Documentation Feedback 17