Datasheet

AM26LV32E
www.ti.com
SLLS849A APRIL 2008REVISED MAY 2008
SWITCHING CHARACTERISTICS
over recommended operating free-air temperature range (unless otherwise noted)
PARAMETER TEST CONDITIONS MIN TYP
(1)
MAX UNIT
t
PLH
Propagation delay time, low- to high-level output 8 16 26 ns
See Figure 1
t
PHL
Propagation delay time, high- to low-level output 8 16 26 ns
t
t
Transition time See Figure 1 5 ns
t
PZH
Output-enable time to high level See Figure 2 17 40 ns
t
PZL
Output-enable time to low level See Figure 3 10 40 ns
t
PHZ
Output-disable time from high level See Figure 2 20 40 ns
t
PLZ
Output-disable time from low level See Figure 3 16 40 ns
t
sk(p)
Pulse skew See Figure 1
(2)
4 6 ns
t
sk(o)
Pulse skew See Figure 1
(3)
4 6 ns
t
sk(pp)
Pulse skew (device to device) See Figure 1
(4)
6 9 ns
f
(max)
Maximum operating frequency See Figure 1 32 MHz
(1) All typical values are at V
CC
= 3.3 V, T
A
= 25°C.
(2) t
sk(p)
is |t
pLH
– t
pHL
| of each channel of same device.
(3) t
sk(o)
is the maximum difference in propagation delay times between any two channels of same device switching in the same direction.
(4) t
sk(pp)
is the maximum difference in propagation delay times between any two channels of any two devices switching in the same
direction.
ESD PROTECTION
PARAMETER TEST CONDITIONS TYP UNIT
HBM ±15
Receiver input IEC61000-4-2, Air-Gap Discharge ±15 kV
IEC61000-4-2, Contact Discharge ±8
Copyright © 2008, Texas Instruments Incorporated Submit Documentation Feedback 5
Product Folder Links: AM26LV32E