Datasheet

AM26LV32E
SLLS849A APRIL 2008REVISED MAY 2008
www.ti.com
RECOMMENDED OPERATING CONDITIONS
MIN NOM MAX UNIT
V
CC
Supply voltage 3 3.3 3.6 V
V
IH
Enable high-level input voltage 2 5.5 V
V
IL
Enable low-level input voltage 0 0.8 V
V
IC
Common-mode input voltage –7 7 V
V
ID
Differential input voltage –7 7 V
I
OH
High-level output current –5 mA
I
OL
Low-level output current 5 mA
T
A
Operating free-air temperature –40 85 °C
ELECTRICAL CHARACTERISTICS
over recommended ranges of common-mode input, supply voltage, and operating free-air temperature (unless otherwise
noted)
PARAMETER TEST CONDITIONS MIN TYP
(1)
MAX UNIT
Positive-going input threshold voltage,
V
IT+
0.2 V
differential input
Negative-going input threshold voltage,
V
IT–
–0.2 V
differential input
V
hys
Input hysteresis (V
IT+
– V
IT–
) 35 mV
V
IK
Input clamp voltage, G and G I
I
= –18 mA –1.5 V
V
ID
= 200 mV, I
OH
= –5 mA 2.4 3.2
V
OH
High-level output voltage V
V
CC
V
ID
= 200 mV, I
OH
= –100 μA
0.1
V
ID
= –200 mV, I
OL
= 5 mA 0.17 0.5
V
OL
Low-level output voltage V
V
ID
= –200 mV, I
OL
= 100 μA 0.1
I
OZ
High-impedance state output current V
O
= V
CC
or GND ±50 μA
I
off
Output current with power off V
CC
= 0 V, V
O
= 0 or 5.5 V ±100 μA
V
I
= 10 V 1.5
I
I
Line input current Other input at 0 V mA
V
I
= –10 V –2.5
I
I
Enable input current, G and G V
I
= V
CC
or GND ±1 μA
r
i
Input resistance V
IC
= –7 V to 7 V, Other input at 0 V 4 17 k
I
CC
Supply current (total package) G, G = V
CC
or GND, No load, Line inputs open 8 17 mA
C
pd
Power dissipation capacitance
(2)
One channel 150 pF
(1) All typical values are at V
CC
= 3.3 V, T
A
= 25°C.
(2) C
pd
determines the no-load dynamic current consumption: I
S
= C
pd
× V
CC
× f + I
CC
4 Submit Documentation Feedback Copyright © 2008, Texas Instruments Incorporated
Product Folder Links: AM26LV32E