Datasheet
Deviceoperationin Auto 1 or
Auto 2 mode
ChangetoManualmode?
* Sample: Samplesandconvertschannelselectedin ‘framen-1’
* Mux : Selectschannelincrementedfrompreviousframeasperautosequencethischannelwillbe
acquiredinthisframeandsampledatstartof ‘framen+1’
* Range: Asprogrammedin ‘framen-1’ . Appliestochannelselectedforacquisitionincurrentframe.
* SDI : Programmingfor ‘framen +1’
DI15..12 = 0001 binary …. Selectsmanualmode
DI11=1 enablesprogrammingof ‘rangeandGPIO’
DI10..7 = binaryaddressofchannel
DI6.. Asperrequiredrangeforchanneltobeselected
DI5=0 .. Nopowerdown
DI4..0… asperGPIOsettings
*SDO : DO15..0 address (orGPIOdata) & conversiondataofchannelselectedin ‘framen -1’
* GPIO:
O/P: latchedon CS
fallingedgeasperDI3..0 writteninframen-1’
I/P: Inputstatuslatchedonfallingedgeof CS
andtransferredseriallyonSDOinthesame
frame
No
Yes
CS
CS
Continueoperation in manualmode
CS
Frame: n-1
Frame: n
Request
forManual
mode
* Sample: Samplesandconvertschannelselectedin ‘framen’
* Mux : Selectschannelprogrammedin ‘framen’(Manualmode) thischannelwillbeacquiredinthis
frameandsampledatstartof ‘framen+2’
* Range: Asprogrammedin ‘framen’. Appliestochannelselectedforacquisitionincurrentframe.*
SDI : Programmingfor ‘framen+2’
DI15..12 = 0001 binary …. Tocontinueinmanualmode
DI11=1 enablesprogrammingof ‘rangeandGPIO’
DI10..7 = binaryaddressofchannel
DI6.. Asperrequiredrangeforchanneltobeselected
DI5=0 .. Nopowerdown
DI4..0… asperGPIOsettings
*SDO : DO15..0 address (orGPIOdata) & conversiondataofchannelselectedin ‘framen’
* GPIO:
O/P: latchedon CS
fallingedgeasperDI3..0 writteninframe ‘n’
I/P: Inputstatuslatchedonfallingedgeof CS
andtransferredseriallyonSDOinthesame
frame
CS
Frame:
n+1
Entryinto
Manual
Mode
* Sample: Samplesandconvertschannelselectedin ‘framen+1’
* Mux : Selectschannelprogrammedin ‘framen+1’ (Manualmode), thischannelwillbeacquiredin
thisframeandsampledatstartof ‘framen+3’
* Range: Asprogrammedin ‘framen+1’ . Appliestochannelselectedforacquisitionincurrentframe.*
SDI : Programmingfor ‘framen+3’
DI15..12 = 0001 binary …. Selectsmanualmode
DI11=1 enablesprogrammingof ‘rangeandGPIO’
DI10..7 = binaryaddressofchannel
DI6.. Asperrequiredrangeforchanneltobeselected
DI5=0 .. Nopowerdown
DI4..0… asperGPIOsettings
*SDO : DO15..0 address (orGPIOdata) & conversiondataofchannelselectedin ‘framen+1’
* GPIO:
O/P: latchedon CS
fallingedgeasperDI3..0 writteninframen+1’
I/P: Inputstatuslatchedonfallingedgeof CS
andtransferredseriallyonSDOinthesame
frame
CS
Frame:
n+2
Operation
inManual
mode
ADS7950, ADS7951, ADS7952, ADS7953
ADS7954, ADS7955, ADS7956, ADS7957
ADS7958, ADS7959, ADS7960, ADS7961
SLAS605A –JUNE 2008–REVISED JANUARY 2010
www.ti.com
Figure 50. Entering and Running in Manual Channel Sequencing Mode
28 Submit Documentation Feedback Copyright © 2008–2010, Texas Instruments Incorporated
Product Folder Link(s): ADS7950, ADS7951, ADS7952, ADS7953 ADS7954, ADS7955, ADS7956, ADS7957 ADS7958,
ADS7959, ADS7960, ADS7961