Datasheet

ADS7807
13
SBAS022D
www.ti.com
CALIBRATION
HARDWARE CALIBRATION
To calibrate the offset and gain of the ADS7807 in hardware,
install the resistors shown in Figure 7a. Table VI lists the
hardware trim ranges relative to the input for each input
range.
OFFSET ADJUST GAIN ADJUST
INPUT RANGE RANGE (mV) RANGE (mV)
±10V ±15 ±60
0 to 5V ±4 ±30
0 to 4V ±3 ±30
TABLE VI. Offset and Gain Adjust Ranges for Hardware
Calibration (see Figure 7a).
FIGURE 7b. Circuit Diagrams (Without Hardware Trim).
SOFTWARE CALIBRATION
To calibrate the offset and gain in software, no external
resistors are required. However, to get the data sheet speci-
fications for offset and gain, the resistors shown in Figure 7b
are necessary. See the No Calibration section for more
details on the external resistors. Refer to Table VIII for the
range of offset and gain errors with and without the external
resistors.
NO CALIBRATION
Figure 7b shows circuit connections. Note that the actual
voltage dropped across the external resistors is at least two
orders of magnitude lower than the voltage dropped across
the internal resistor divider network. This should be consid-
ered when choosing the accuracy and drift specifications of
the external resistors. In most applications, 1% metal-film
resistors will be sufficient.
±10V 0V-5V 0V-4V
FIGURE 7a. Circuit Diagrams (With Hardware Trim).
±10V 0V-5V 0V-4V
200
1
2
3
4
5
6
AGND2
REF
CAP
R2
IN
AGND1
R1
IN
+
+
2.2µF
2.2µF
1M
+5V
50k
+5V
100
33.2k
50k
V
IN
200
1
2
3
4
5
6
AGND2
REF
CAP
R2
IN
AGND1
R1
IN
+
+
2.2µF
2.2µF
1M
+5V
50k
50k
33.2k
100
V
IN
200
1
2
3
4
5
6
AGND2
REF
CAP
R2
IN
AGND1
R1
IN
+
+
2.2µF
2.2µF
33.2k
100
V
IN
1M
+5V
50k
50k
200
1
2
3
4
5
6
AGND2
REF
CAP
R2
IN
AGND1
R1
IN
+
+
2.2µF
2.2µF
100
+5V
66.5k
V
IN
200
1
2
3
4
5
6
AGND2
REF
CAP
R2
IN
AGND1
R1
IN
+
+
2.2µF
2.2µF
33.2k
100
V
IN
200
1
2
3
4
5
6
AGND2
REF
CAP
R2
IN
AGND1
R1
IN
+
+
2.2µF
2.2µF
33.2k
100
V
IN