Datasheet

ADS1246
ADS1247
ADS1248
SBAS426G AUGUST 2008REVISED OCTOBER 2011
www.ti.com
This integrated circuit can be damaged by ESD. Texas Instruments recommends that all integrated circuits be handled with
appropriate precautions. Failure to observe proper handling and installation procedures can cause damage.
ESD damage can range from subtle performance degradation to complete device failure. Precision integrated circuits may be more
susceptible to damage because very small parametric changes could cause the device not to meet its published specifications.
PACKAGE/ORDERING INFORMATION
(1)
DUAL SENSOR
EXCITATION CURRENT PACKAGE-
PRODUCT NUMBER OF INPUTS VOLTAGE REFERENCE SOURCES LEAD
1 Differential
ADS1246 or External NO TSSOP-16
1 Single-Ended
2 Differential
ADS1247 or Internal or External YES TSSOP-20
3 Single-Ended
4 Differential
ADS1248 or Internal or External YES TSSOP-28
7 Single-Ended
(1) For the most current package and ordering information, see the Package Option Addendum at the end of this data sheet, or see the TI
website at www.ti.com
ABSOLUTE MAXIMUM RATINGS
(1)
Over operating free-air temperature range (unless otherwise noted).
ADS1246, ADS1247, ADS1248
PARAMETER MIN MAX UNIT
AVDD to AVSS 0.3 +5.5 V
AVSS to DGND 2.8 +0.3 V
DVDD to DGND 0.3 +5.5 V
100, momentary mA
Input current
10, continuous mA
Analog input voltage to AVSS AVSS 0.3 AVDD + 0.3 V
Digital input voltage to DGND 0.3 DVDD + 0.3 V
Maximum junction temperature +150 °C
Operating temperature range 40 +125 °C
Storage temperature range 60 +150 °C
(1) Stresses beyond those listed under Absolute Maximum Ratings may cause permanent damage to the device. These are stress ratings
only, and functional operation of the device at these or any other conditions beyond those indicated is not implied. Exposure to
absolute-maximum-rated conditions for extended periods may affect device reliability.
2 Copyright © 20082011, Texas Instruments Incorporated