Datasheet
ABSOLUTE MAXIMUM RATINGS
ADS1174
ADS1178
SBAS373B – OCTOBER 2007 – REVISED SEPTEMBER 2008 ........................................................................................................................................
www.ti.com
This integrated circuit can be damaged by ESD. Texas Instruments recommends that all integrated circuits be handled with
appropriate precautions. Failure to observe proper handling and installation procedures can cause damage.
ESD damage can range from subtle performance degradation to complete device failure. Precision integrated circuits may be more
susceptible to damage because very small parametric changes could cause the device not to meet its published specifications.
ORDERING INFORMATION
For the most current package and ordering information see the Package Option Addendum at the end of this
document, or see the TI web site at www.ti.com .
over operating free-air temperature range unless otherwise noted
(1)
PARAMETER ADS1174, ADS1178 UNIT
AVDD to AGND – 0.3 to +6.0 V
DVDD, IOVDD to DGND – 0.3 to +3.6 V
AGND to DGND – 0.3 to +0.3 V
100, Momentary mA
Input Current
10, Continuous mA
Analog Input to AGND – 0.3 to AVDD + 0.3 V
Digital Input or Output to DGND – 0.3 to IOVDD + 0.3 V
Maximum Junction Temperature +150 ° C
Operating Temperature Range – 40 to +125 ° C
Storage Temperature Range – 60 to +150 ° C
(1) Stresses above these ratings may cause permanent damage. Exposure to absolute maximum conditions for extended periods may
degrade device reliability. These are stress ratings only, and functional operation of the device at these or any other conditions beyond
those specified is not implied.
2 Submit Documentation Feedback Copyright © 2007 – 2008, Texas Instruments Incorporated
Product Folder Link(s): ADS1174 ADS1178