Full Product Manual

These steps are necessary.
1. Always check for uniform rafter alignment. Be sure
to use LP TechShield with the proper thickness for
the required on-center rafter spacing.
2. Provide adequate roof ventilation according to
building code in your area.
3. Panel spacing on ends and edges should be 1/8".
4. Place LP TechShield radiant barrier sheathing
panels with the foil side facing down on the roof
(toward the attic air space). 3/4" minimum air
space required. (See Figures 1 & 2)
5. Fasten the panels a minimum of 6" on center
at supported panel ends and edges and 12" on
center at intermediate supports. 8d nails are
recommended.
6. Protect LP TechShield panels from moisture prior
to and during installation.
7. Use shingle underlayment (or 30# roofing felt) to
cover roof as soon as possible to protect panels
from exposure to adverse weather conditions.
8. Allow sheathing to adjust to atmospheric
conditions before installation of metal roofing.
9. Install all panels with APA and LP TechShield
sheathing trademarks DOWN.
10. Follow the roofing manufacturer’s application
instructions.
Roof sheathing installation
for metal roofing.
LP® TechShield® works fine with a metal roof as long
as you follow the installation instructions, making sure
to leave a 3/4" air space for the foil surface of the
LP TechShield radiant barrier.
Technical Bulletin No. TS-02101
LP® TechShield® Radiant Barrier Sheathing
© 2013 Louisiana-Pacific Corporation. All rights reserved. LP and TechShield are registered trademarks of Louisiana-Pacific Corporation. Printed in U.S.A. NOTE: Louisiana-Pacific Corporation
periodically updates and revises its product information. To verify this version is current, call 800-648-6893. 6/13 LPTS????
Cal. Prop 65 Warning: Use of this product may result in exposure to wood dust, known to the State of California to cause cancer.
For a copy of the warranty or for installation and
technical support visit: www.lpcorp.com/techshield
Phone: 888.820.0325
Email: customer.support@lpcorp.com
Metal roof shakes or panels
3/4" minimum air space
Figure 1
W T R S
Metal roofing
LP TechShield sheathing
foil facing down
3/4" minimum air space
Insulation
Figure 2