Information
A STEP AHEAD
139
Deutsch Tooling
How To Instructions
Step 3:
Measure the exposed
strands to be sure the
crimp length is correct.
Step 1:
1. Choose the correct
AWG for the contact be-
ing used.
2. Measure from the end
of the wire the recom-
mended strip length
according to the contact
size.
3. Place the wire into a
stripping tool at the rec-
ommended strip length.
Strip the wire according to
stripping tool instructions.
Step 2:
1. After stripping, a small
piece of the insulation
should come off.
2. Check for any broken
strands or for a dent in
the wire. If either exist,
the wire is damaged and
should be cut and stripped
again.
Wire Stripping
Leaving the stripped portion of
the insulation on the wire until
prior to crimping will avoid fl ayed
wire strands.
helpful
helpful
hint
hi nt
Correct
Incorrect
Tools for IMC and Quick Connect Series
The Industrial Micro Connect and Quick Connect Series use special contacts and tools. The contacts are smaller and designed
for high pin density. Removal tools along with multiple crimp tools are available and are designed to work with the smaller
contacts and tighter pin arrangements. The common contact system and tools are not compatible with the IMC or QC Series.
Tools for Solid Contacts
Part Number Adjustable Hand Crimp Tools
MH860 QC/IMC #22 crimp tool, adjustable AWG ranges, requires 86-5
86-5 QC/IMC crimp tool positioner for MH860
AF8-TH163 QC/IMC #20 and #16 crimp tool, adjustable AWG ranges
Single Gauge Hand Crimp Tools
AMSC22/1 QC/IMC #22 crimp tool, low cost, only crimps 22 AWG wire
AMSC20/1 QC/IMC #20 crimp tool, low cost, only crimps 20 AWG wire
AMSC16/A/1 QC/IMC #16 crimp tool, low cost, only crimps 16 AWG wire
Insert/Removal Tools
6757-201-2201 Insert/Removal Tool #22
6757-201-2001 Insert/Removal Tool #20
6757-201-1601 Insert/Removal Tool #16