Rev C
Figure 4
4. Verify that all contacts are locked in place by giving a slight tug on each wire with a force of 4.5 to 8.9 N
[1 to 2 lbf].
5. Place a sealing plug, (part number 776363-1 for SDWS and RDWS), into any circuits not loaded with
contacts. The sealing plug should be pushed into the wire entry end of the plug or cap cover until the
flange on the sealing plug is firmly against the seal cover. See Figure 5.
Figure 5
6. When all the contacts have been locked securely into the housing assemblies, complete the assembly
of the connector system by mating the plug assembly with the cap housing assembly or pc board mounted
header until the connector latch is in the fully locked position. An audible “click” will be heard. See
Figure 6.
Plug Assembly
Loaded Contacts
Loaded Contacts
Cap Housing
TPA
TPA
TPA
Screwdriver
Slot in Removal Tool
Engages TPA Through
Removal Tool Slot
Cap Assembly
Cap Cover
Plug Cover
Plug Assembly
Sealing Plug
Flange
Sealing Plug