1. SCOPE
1.1. Content
This specification covers the performance, tests and quality requirements for Type XII contacts
assembled in the G series connector housing. These contacts are primarily intended for use where the
coupling means is provided separately from the individual contacts.
1.2. Qualification
When tests are performed on the subject product line, the procedures specified in 109-Series Test
Specifications shall be used. All inspections shall be performed using the applicable inspection plan
and product drawing.
2. APPLICABLE DOCUMENTS
The following documents form a part of this specification to the extent specified herein. In the event of
conflict between the requirements of this specification and the product drawing, the product drawing
shall take precedence. In the event of conflict between the requirements of this specification and the
referenced documents, this specification shall take precedence.
2.1. TE Connectivity (TE) Documents
A. 109-1: General Requirements for Test Specifications
B. 109 Series: Test Specifications as indicated in Figure 1.
C. 114-10005: Contact, Type XII, Application Of
D. 501-143: Test Report
2.2. Military Standard
MIL-W-16878: Wire, Electrical, Insulated, High Temperature
3. REQUIREMENTS
3.1. Design and Construction
Product shall be of the design, construction and physical dimensions specified on the applicable
product drawing.
3.2. Material
Contact: Copper, tin-lead, gold over nickel or silver over nickel plating
3.3. Ratings
Temperature:
1. -55° to 105°C for tin-lead
2. -55° to 125°C for gold over nickel or silver ove r nickel
3.4. Performance and Test Description
The product is designed to meet the electrical, mechanical and environmental performance
requirements specified in Figure 1. All tests are performed at ambient environmental conditions per
Test Specification 109-1 unless otherwise specified.