Information

33
MTA-156
.156 [3.96]
Product Facts
Connectors and headers for
2 through 24 positions; wire
sizes of 18, 20, 22, 24 and
26 AWG [0 .9– 0.12 mm
2
]
Connectors and headers,
except shrouded headers,
are end-to-end stackable
Quad Connectors for higher
current rating (page 54)
Posted connectors for 2,3,
4,6,9,12,15 and 24 posi-
tions
Card edge connectors for
3, 6,9,12,15,18 and 20
through 24 positions
Connectors preloaded with
IDC contacts
All contacts are slotted for
insulation displacement
(IDC) termination technique
Connector styles include
both closed end and feed-
thru, with and without lock-
ing ramps and polarizing
tabs
Molded ribs on housing do
not allow reverse mating
Contacts are lubricated for
fretting corrosion protection
Benefits derived from the
MTA-156 system include
increases quality and ease
of handling such as—
One-step assembly
No wire stripping
No contact damage
Reduced wiring errors
Simpler tooling
Simple maintenance
and repair
Meets the material require-
ments of Table 23.1 of
UL 1410 Standards for
Television Receiver and
Video Products (wire-to-
post connectors only)
Recognized under the
Component Program of
Underwriters
Laboratories Inc.,
File No. E28476
Certified by Canadian
Standards
Association,
File No. LR7189
R
R
MTA-156 connectors
accept discrete and ribbon
cable wire sizes ranging
from 18 26 AWG
[0.9– 0.12 mm
2
] with maxi-
mum insulation outside
diameter.095 [2.41] for sin-
gle wire and .070 [1.78] for
mass termination of wires.
Tin plated solid, fused
stranded or stranded (7, 16,
and 19 strands) wire with
PVC insulation can be used
on 18 AWG [0.8 0.9 mm
2
]
MTA-156 connectors; 7, 10,
and 19 stranded wire on
20 AWG [0.5 0.6 mm
2
]
MTA-156 connectors; and 7
and 19 stranded wire on
22 26 AWG [0.4 0.12 mm
2
]
MTA-156 connectors.
Only one wire to be termi-
nated into an IDC contact
slot.
Mass termination of wire
provides the lowest applied
cost because it drastically
reduces the labor content
of virtually any cable or har-
ness assembly required.
Technical Documents
Product Specification
108-1051 MTA-156 Connectors
Application Specifications
114-1020 MTA-156 Connectors,
Posted Connectors and
Card Edge Connectors
114-1032 MTA-156 Ribbon Cable
Assembly
Note: Refer to page 70 for approved
wire listings.
Performance Data*
Voltage Rating 600 vac
Current Rating
7 amp max. for MTA-156 Connector
Low-Level Resistance
3.0 m max. initial
Dielectric Withstanding Voltage
2200 vac/1 min.
Insulation Resistance
5000 M min. initial
Operating Temperature
55 C to 105 C
*Refer to the Product Specification
for additional electrical, mechanical
and environmental performance
tests and requirements.
The wire-to-post connector
housing material is flame
retardant thermoplastic,
either UL94V-2 or UL94V-0
rated.
A full line of .156 [3.96]
centerline headers com-
pletes the system. Headers
are available with straight
or right-angle posts, in flat
friction lock and shrouded
styles. Headers are available
in 2 through 24 positions.
.156 [3.96] Centerline MTA-156 IDC Connectors and Headers
MTA, CST-100 II, SL-156 and
AMP Economy Power (EP) Connectors
Catalog 82056 Dimensions are in inches and Dimensions are shown for USA: 1-800-522-6752 South America: 55-11-2103-6000
Revised 6-08 millimeters unless otherwise reference purposes only. Canada: 1-905-470-4425 Hong Kong: 852-2735-1628
specified. Values in brackets Specifications subject Mexico: 52-55-1106-0800 Japan: 81-44-844-8013
www.tycoelectronics.com are metric equivalents. to change. C. America: 57-1-254-4444 UK: 44-208-420-8341