Test Description Requirem ent Procedure
Tem perature rise vs current. 30°C m axim um tem perature rise at
specified current.
EIA-364-70, Method 1.
Stabilize at a single current level
until 3 readings at 5 m inute intervals
are within 1°C.
See Figure 4.
MECHANICAL
Vibration, random . No discontinuities of 1 m icrosecond
or longer duration.
See Note.
EIA-364-28, Test Condition V,
Condition F.
Subject mated specim ens to 20.71
G's rm s between 50 to 2000 Hz.
Fifteen m inutes in each of 3
mutually perpendicular planes.
See Figure 5.
Mechanical shock. No discontinuities of 1 m icrosecond
or longer duration.
See Note.
EIA-364-27, Method A.
Subject mated specim ens to 50 G's
half-sine shock pulses of 11
milliseconds duration. Three shocks
in each direction applied along 3
mutually perpendicular planes, 18
total shocks.
See Figure 5.
Durability. See Note. EIA-364-9.
Mate and unm ate gold flash
specim ens for 100 cycles, and 30
ìin gold specim ens for 500 cycles
at a maxim um rate of 200 cycles
per hour.
Mating force. W ithout W ith
Ground Indents
Size Posn (N [lbf] maxim um )
1 9 12.5 [2.8] 133.4 [30]
2 15 20.9 [4.7] 146.8 [33]
3 25 34.7 [7.8] 164.6 [37]
4 37 51.6 [11.6] 177.9 [40]
5 50 69.4 [15.6] 195.7 [44]
EIA-364-13.
Measure force necessary to m ate
specim ens at a m axim um rate of
25.4 m m [1 in] per m inute.
Unm ating force. W ithout W ith
Ground Indents
Size Posn (N [lbf] maxim um)
1 9 12.5 [2.8] 133.4 [30]
2 15 20.9 [4.7] 146.8 [33]
3 25 34.7 [7.8] 164.6 [37]
4 37 51.6 [11.6] 177.9 [40]
5 50 69.4 [15.6] 195.7 [44]
EIA-364-13.
Measure force necessary to unm ate
specim ens at a m axim um rate of
25.4 m m [1 in] per m inute.
Contact insertion force. 13.3 N [3 lbf] m axim um per contact. EIA-364-5.
Measure force necessary to insert
contact into housing.
Figure 1 (continued)
Rev F 3 of 10