Datasheet

501-45
Rev B 4 of 8
2. SUMMARY OF TESTING
2.1. Test Report CTL5730-115-016|
A. Examination of Product - All Test Groups
All specimens submitted for testing were selected from normal current production lots. They were
inspected and accepted by the Product Assurance Depsartment of the Capital Goods Business
Unit.
B. Termination Resistance, Dry Circuit - Test Groups 1, 2 and 3
All termination resistance measurements, taken at 100 milliamperes DC and 50 millivolts open
circuit voltage were less than 15 milliohms.
Test
Group
Number of
Data Points
Condition
Termination Resistance
Min Max Mean
1 400
Initial 4.63 6.13 5.276
After mechanical 4.69 14.56 6.266
2 400
Initial 4.31 5.14 4.916
After temperature life 5.28 10.53 5.719
3 400
Initial 4.11 5.87 4.960
After mixed flowing gas 4.30 9.95 5.411
All values in milliohms.
NOTE
Figure 3
C. Insulation Resistance - Test Group 4
All insulation resistance measurements were greater than 5000 megohms initially and 1000
megohms after testing.
D. Dielectric Withstanding Voltage - Test Group 4
No dielectric breakdown or flashover occurred when a test current was applied between adjacent
contacts.
E. Random Vibration - Test Group 1
No discontinuities were detected during vibration testing. Following vibration testing, no cracks,
breaks, or loose parts on the specimens were visible.
F. Physical Shock - Test Group 1
No discontinuities were detected during mechanical shock testing. Following mechanical shock
testing, no cracks, breaks, or loose parts on the specimens were visible.
G. Connector Mating Force - Test Group 1
All mating force measurements were less than 12 ounces per contact.