Information

108-1092
Test Description Requirement Procedure
Humidity-temperature cycling. See Note. TE Spec 109-23-3, Condition B.
Subject mated connectors to 10
humidity-temperature cycles
between 25 and 65°C at 95% RH.
Mixed flowing gas. See Note. TE Spec 109-85-3.
Subject mated connectors to
environmental class III for 20 days.
Temperature life. See Note. TE Spec 109-43.
Subject mated connectors to
temperature life at 105°C for 500
hours.
Shall meet visual requirements, show no physical damage and shall meet requirements of
NOTE
additional tests as specified in Test Sequence in Figure 2.
Figure 1 (end)
3.6. Product Qualification and Requalification Test Sequence
Test or Examination
Test Group (a)
1 2 3 4 5 6 7 8
Test Sequence (b)
Examination of product 1,9 1,6 1,6 1,4 1,5 1,8 1,3 1,5
Termination resistance 3,7 2,5 2,5 2 2,4
Dielectric withstanding voltage 3,7
Insulation resistance 2,6
Temperature rise vs current 3
Vibration 5
Physical shock 6
Mating force 2 2
Unmating force 8 4
Durability 4 3 3 3
Solderability 2
Thermal shock 4
Humidity-temperature cycling 4 5
Mixed flowing gas 3(c)
Temperature life 4
(a) See paragraph 4.1.A.
NOTE
(b) Numbers indicate sequence in which tests are performed.
(c) Precondition samples with 10 cycles durability.
Figure 2
Rev F 4 of 8